Sensor head parameter setting (SETd)
Configures the sensor head parameters.
This setting is not required if the controller and the sensor head are purchased as a set (Model: ZL2-ZLL
□
-
□
LK) as it is already configured.
Install direction setting (SET0)
Configures the install direction of the sensor head. This setting must be configured after installing the cylinder head to the cylinder.
If the system is used without configuring this setting, correct detection or output cannot be achieved.
Factory setting :
Setting :
or
The behavior differs depending whether the sensor head is connected or not.
Return to
*
*
Press
□
When the sensor head
connected (automatic setting)
1 second later
After judging the
install direction
When the sensor head is not
connected (manual setting)
Reciprocate the
cylinder a few times
while checking the
toggle of the sensor
head LED ON/OFF.
The setting
value matches
the sensor head
install direction is
displayed.
Press
□
1 second later
Press
□
1 second later
Return to
Use
△
or
▽
key to
change the setting
values.
Note 1) If the
□
key is pressed before the setting judgment by automatic judgment, the display returns to “ ” without any change.
Threshold value setting (SET1)
Use this setting to set threshold values for each channel.
Factory setting
Input value
Window comparator mode
Hysteresis mode
Threshold (L2)
600
0 to 1000
Upper threshold
ON point
Threshold (L1)
400
0 to 1000
Lower threshold
OFF point
Note1) Input condition
L2
>
L1+1
<About TEACH setting>
While actually moving the cylinder (hand), set the threshold based on the value displayed.
Because the threshold is set based on the displayed value, perform this task while the sensor head is connected.
(If TEACH setting is entered without setting the sensor head, E-1 is displayed)
It would be the same area as the threshold storage location. To see the stored value, use SET1.
Output behavior when configured with the tolerance = 10 and the displayed value 525 (in Window comparator mode)
10
10
2
Fixed hysteresis
Fixed hysteresis
Tolerance
Tolerance
515
513
537
525
535
Display value
L1
L2
2
Return to
INPT: Use the
△▽
buttons
to set the threshold
TEAC: Configure the
threshold based on
the actual position
Press
□
Press
□
Press
□
Press
□
Press
□
Press
□
Press
□
Press
□
Press
□
Setting CH is displayed
CH1 to 4: Individual settings
for the selected CH
ALL: Sets CH1 to 4 in a row
Set the threshold L2.
The indicator corresponding
to the setting CH turns on.
The current position is
displayed.
Move to the L2 setting
position. The indicator
corresponding to the
setting CH blinks.
Backlight color: red
Backlight color: red
Use
△
or
▽
key to
change the setting
values.
Input value: 0 to 1000
Factory setting: 600
Set the threshold L1.
The indicator corresponding
to the setting CH turns on.
Backlight color: green
Backlight color: green
Use
△
or
▽
key to
change the setting
values.
Input value: 0 to 1000
Factory setting: 400
1 second
later
Press
□
Press
□
Press
□
ALL: when selected, moves to the
next CH setting
(If not completed to CH4)
1P: 1-Point teaching
threshold setting
2P: 2-Point teaching
threshold setting
Set the threshold.
Use
△
or
▽
key to
change the tolerance
values.
Input value: 1 to 1000
Setting CH is displayed
CH1 to 4: Individual settings
for the selected CH
ALL: Sets CH1 to 4 in a row
Setting CH is displayed
CH1 to 4: Individual settings
for the selected CH
ALL: Sets CH1 to 4 in a row
Use
△
or
▽
key to select
the setting CH
Use
△
or
▽
key to select
the setting CH.
Use
△
or
▽
key to select
the setting CH.
The current position is
displayed. Move to the
setting position. The
indicator corresponding
to the setting CH blinks.
The current position is
displayed. Move to the
L1 setting position. The
indicator corresponding
to the setting CH blinks.
△
or
▽
L2 = set to the
displayed value
△
or
▽
Set to:
L2 = displayed value +
tolerance value
L1 = displayed value -
tolerance value
ALL: when selected, moves
to the next CH setting
(If not completed to CH4)
Press
□
ALL: when selected, moves to the next CH setting
(If not completed to CH4)
Installed cylinder model setting (SET2)
Change this setting in accordance with the cylinder model that the cylinder head will be set into.
Factory setting : 18
Setting :
1 to 20
Set value
Installed cylinder model
8
NHBDSL:25
16
NHB
□
PG:40,50
17
AFDPPG(L):14,18
18
NHB
□
PG:8,10,16,20,25,30
NHBDSL:12,16,20
AFDPG(L):6,8,12,25
NHB
□
PGL,NHB
□
P(A),NHB
□
S
NHE1D,NHC1D,NHL1D
BDAS,NDAS,PBDAS
CDAS,SGDA,MGA,MGT,TBDA,ARS,
*For information about other cylinders, contact Koganei.
Output mode setting (SET3)
Use this setting to set the output mode for each channel.
Press
□
Press
□
Press
□
Setting CH is displayed
CH1 to 4: select the setting CH
Use
△
or
▽
key to select
the setting CH.
Set the switch output mode
The indicator corresponding
to the setting CH blinks.
Use
△
or
▽
key to select the switch output
mode from the list below.
<Switch output mode>
: Output OFF
: Window comparator mode (factory setting)
: Hysteresis mode
The set value is displayed for 1 second.
1 second later
Return to
5642
5642
5642
ZLL1
ZLL2
ZLL3
Refer to the parameter code embossed on the sensor head, and follow the example
below to enter the parameter code.
The parameter code is embossed at the position shown in the sensor head diagrams on
the right with the format display side facing up.
(Opposite to the “E※※※” impression)
Ex.) For the parameter code “5642”
Parameter 1: 1.56
Parameter 2: 1.42
❻
❺
.
.
Press
□
Press
□
Press
□
Return to
Use
△
or
▽
key to change
the setting values.
Input values: 1.30 to 1.70
Use
△
or
▽
key to change
the setting values.
Input values: 1.30 to 1.70
Parameter 1
Parameter 2
Press
□
Press
□
Press
□
Return to
Use the
△
or
▽
key to
configure according to
the installed cylinder.
Input value: 1 to 20