MJ400271F1
- 20 -
Paramet er
sett ing No.
Set Item
Default
Value
0
Setting of output 2 preset value: 001
〜
100(unit:%FS)
Indicated only when [50]/[51] are selected in P-20.
P-26
Integrating pulse
outp ut rate
10
A
B
C
D
0
1
9999
A
B
C
D
9
9
9
9.
(Lower 4 digits)
9
(Upp er 4 digits)
Setting of output 2 preset value: 0000 – 9999
Indicated only when [40]/[41] are selected in P-20.
P-25
OUT2 integrated flow
rate reach p reset
setting lower 4 digits
Setting of output 2 preset value: 0000 – 9999
Indicated only when [40]/[41] are selected in P-20.
*
The decimal p oint is shown in lower 4 digits. The
position of the decimal point varies dep ending on specification flow rates.
P-24
OUT2 integrated flow
rate reach p reset
setting upper 4 digits
Indicated only when [20]/[21] or [30]/[31] are selected in P-20.
P-23
Dead time value
Indicated only when [10]/[11] or [20]/[21] or [30]/[31] are selected in P-20.The up per limit, lower limit
and upp er/lower limit are output when each condition is met during this p eriod continuously.
P-22
OUT2 instantaneous
flow rate lower limit
preset setting
9999
A
B
C
D
9
9
9
00
A
B
C
D
0
0
Setting of output 2 preset value: 00
〜
30
(
unit:sec.)
The function works according to results of comp arison between the indicated value and the preset value.
[OUT2 setting]
00:The event output mode is not used.
10:Instantaneous flow rate up per limit output
Outp ut when “instantaneous flow rate value
≧
P-21 up per limit preset value”.
20:Instantaneous flow rate lower limit output
Outp ut when “instantaneous flow rate value
≦
P-22 lower limit preset value”.
30:Instantaneous flow rate up per/lower limit output
Output when “instantaneous flow rate value
≧
P-21 upper limit p reset value” or “instantaneous
flow rate value
≦
P-22 lower limit preset value”.
※
The alarm is constantly output when “P-11 up per limit preset value
≦
P-22 lower limit preset
value” is set.
40: Integrated flow rate reach
Output when “integrated flow rate value
≧
P-23 upp er limit preset value”.
50:Pulses of approx. 50 ms are output every preset value of P-26 of the integrated flow rate value.
P-21
OUT2 instantaneous
flow rate upper limit
preset setting
9999
A
B
C
D
0000
A
B
C
D
0
0
0
9
9
9
9
Setting of output 2 preset value: 0000 – 9999
Indicated only when [10]/[11] or [30]/[31] are selected in P-20.
0
Setting of output 2 preset value: 0000 – 9999
Description of set values
P-20
OUT2 output
selection
00
A
B
C
D
21:Instantaneous flow rate lower limit : OFF
30:Instantaneous flow rate upper/lower limit : ON
31:Instantaneous flow rate upper/lower limit : OFF
40:Integrated flow rate reach : ON
41:Integrated flow rate reach : OFF
50:Integrating pulse : ON
0
0
00:No
10: Instantaneous flow rate up per limit : ON
11: Instantaneous flow rate up per limit : OFF
20:Instantaneous flow rate lower limit : ON
51:Integrating pulse :OFF
※
ON:Normal output, OFF:Inverted output
Summary of Contents for EX-700R
Page 1: ...MJ400271F1 Mass Flow Meter with indicator EX 700R Instruction Manual...
Page 5: ...MJ400271F1 4...
Page 6: ...MJ400271F1 5...
Page 7: ...MJ400271F1 6 Attension EX 700R and EX 700 old model are different adapter inputs...
Page 10: ...MJ400271F1 9...
Page 11: ...MJ400271F1 10...
Page 12: ...MJ400271F1 11...
Page 13: ...MJ400271F1 12...
Page 14: ...MJ400271F1 13 EX 700R and EX 700 old model are different adapter inputs...
Page 15: ...MJ400271F1 14...
Page 16: ...MJ400271F1 15...
Page 17: ...MJ400271F1 16...
Page 25: ...MJ400271F1 24...