1. Foreword 

Thank you for your selection of the Digital Mass Flow Meter EX-700R.   

Prior to using your new equipment, please read this manual thoroughly to ensure it is used in a safe manner. 

Please keep in mind that this instruction manual may be revised without notice. 

 

 

2. Precautions for Handling 

Prior to use 

All the products have been assembled and adjusted one by one in accordance with the specifications.   

The type of gas to use, flow rate and other data are shown on the ID plate attached to the back of the case. 

Check the ID plate and make sure these specifications meet your order. 

 

Date shown on the ID plate 

 

MODEL

Model name

Use of Needle valve

Flow rate

Output 

Model name 

[EX-700R] 

: Mass Flow Meter 

Needle Valve 

[0] 

[V] 

: without needle valve   
: with needle valve   

Flow rate

 

[F1]10SCCM

[F14]500SLM 

Output 

[I] 

: Current 4-20mA 

 

Flow range table 

 
 
 
 
 
 
 
 

 

 

GAS : Applicable gas 

 

FLOW RATE 

SCCM =ml/min (0

 1atm(101.325kPa)) 

SLM =l/min (0

, 1atm(101.325kPa)) 

 

CALIB.: Calibration gas 

 

PRESSURE : Supply pressure /Outlet pressure 

 

SERIAL No. 

 
 
 
 
 
 
 
 
 
 

M ain Body Block  25mm square

Code

F1

F2

F3

F4

F5

F6

F7

F8

Flow rate

10SCCM

50SCCM

100SCCM

500SCCM

1SLM

5SLM

10SLM

20SLM

M ain Body Block  34mm square

Code

F9

F10

F11

Flow rate

50SLM

100SLM

200SLM

M ain Body Block  40mm square

Code

F12

F13

F14

Flow rate

300SLM

400SLM

500SLM

Summary of Contents for EX-700R

Page 1: ...MJ400271F1 Mass Flow Meter with indicator EX 700R Instruction Manual...

Page 2: ...Ignoring this symbol and handling the product incorrectly may result in loss of life or serious injury Ignoring this symbol and handling the product incorrectly may result in personal injury or damage...

Page 3: ...Precautions for Handling 3 Overview 4 Standard Specifications 5 ExternalView 6 Applicable Connectors and Pin Assignment 7 Operation 8 Troubleshooting 9 Precautions for maintenance 10 After sale Servi...

Page 4: ...ID plate and make sure these specifications meet your order Date shown on the ID plate MODEL Model name Use of Needle valve Flow rate Output Model name EX 700R Mass Flow Meter Needle Valve 0 V withou...

Page 5: ...MJ400271F1 4...

Page 6: ...MJ400271F1 5...

Page 7: ...MJ400271F1 6 Attension EX 700R and EX 700 old model are different adapter inputs...

Page 8: ...g of flow rates without a need of troublesome flow rate compensation calculation by temperature pressure 3 1 Principle of operation The flow detect sensor is designed with heating wire resistance wire...

Page 9: ...ashing Integrated flow rate indication range 3 8 digit indication Max 99 999 999 indication limiter flashing The units of indication are the same as the instantaneous flow rate Digital communication R...

Page 10: ...MJ400271F1 9...

Page 11: ...MJ400271F1 10...

Page 12: ...MJ400271F1 11...

Page 13: ...MJ400271F1 12...

Page 14: ...MJ400271F1 13 EX 700R and EX 700 old model are different adapter inputs...

Page 15: ...MJ400271F1 14...

Page 16: ...MJ400271F1 15...

Page 17: ...MJ400271F1 16...

Page 18: ...0 OUT2 instantaneous flow rate lower limit preset setting OUT1 instantaneous flow rate lower limit preset setting Dead time value OUT1 integrated flow rate reach preset setting upper 4 digits OUT1 in...

Page 19: ...Reference condition on flow rate 1 A B C D Low cut function selection 0 5 F S P 01 Low cut function selection 3 A B C D Input signals are measured during the period set here and an average value is c...

Page 20: ...rate upper limit preset setting Indicated only when 10 11 or 30 31 are selected in P 10 Description of set values P 10 OUT1 output selection 0 0 The function works according to results of comparison...

Page 21: ...Instantaneous flow rate upper limit output Output when instantaneous flow rate value P 21 upper limit preset value 20 Instantaneous flow rate lower limit output Output when instantaneous flow rate val...

Page 22: ...setting Indicated only when 0 is selected in P 10 1 000 A B C D 1 0 0 0 0 500 1 500 Transmission speed selection 2 A B C D 0 Transmission speed Not indicated when is selected in P 40 Fixed value Star...

Page 23: ...as keeps flowing The sensor must be replaced Please send it to our sales office or the dealer 3 The output will not become zero more than 45 minutes after power on a The control valve is leaking inter...

Page 24: ...and expense provide a replacement product or repair the failed product at the KOFLOC factory The scope of warranty is limited to the product itself and KOFLOC shall not be held liable whatsoever for d...

Page 25: ...MJ400271F1 24...

Reviews: