MJ400306A1
20
12. Changing Over the Operation Modes
The valve has three operation modes; “control mode,” “fully closed mode” and “fully
opened mode.” When the equipment is shipped, it is in the control mode. It can be forced
to the “fully closed mode” (valve fully closed) or “fully opened mode” (valve fully opened).
Each time the [RUN] key is pressed, the mode is changed over between “control” and
“fully closed” alternately as shown below. To change the control mode to the fully opened
mode, press and hold the [RUN] key for 2 seconds or longer.
Control mode
[RUN] key (less than
[RUN] key
2 sec)
(less than 2 sec)
Fully closed mode
[RUN] key (2 sec or longer)
[RUN] key (less than
[RUN] key
2 sec)
(2 sec or longer)
Fully opened mode
◎
Indication of the operation modes
The operation modes are indicated on the indicator as shown below:
Operation Mode
Indication
Remarks
Fully closed
0FF
After
0FF
is shown for 10 seconds, instantaneous flow
rate is indicated.
Control
0N
After
0N
is shown for 1 second, instantaneous flow rate
is indicated.
Fully opened
FULL
After
FULL
is shown for 1 second, instantaneous flow
rate is indicated.