3.8 Environmental specification
To the requirements of IEC 60945 3
rd
Edition. The measure environmental
specifications are as follows:
(1) Temperature and humidity
Operating temperature
Storage temperature
Humidity
Antenna -25
o
C - +55
o
C +70
o
C
93%+/-3% at +40
o
C
Display -15
o
C - +55
o
C +55
o
C
93%+/-3% at +40
o
C
(2) Vibration
2-5Hz up to 13.2 Hz: Amp/-1mm +/-10% (Maximum acceleration 7m/s
2
at
13.2Hz)
13.2 Hz up to 100Hz: Maximum acceleration 7 m/s
2
constant
3.9 Mechanical specifications
Dimensions: W (Width) x Depth x Height, Unit in mm
Weight: Unit in kg
Antenna unit:
RB718AP: 325 x 390 x 450, 23 kg (for 4ft system), 25 kg (for 6ft system)
RB719AP: 325 x 470 x 450, 27 kg (for 4ft system), 29 kg (for 6ft system)
Aerial Swing circle: 1346 for 4 ft, 1970 for 6 ft
Display unit:
450 x 390 x 366, 12 kg
Operation unit:
354 x 130 x 49, 2 kg
3-4