Chapter 8 MDC-1810P/1820P Series
Trouble Shooting And On Board Servicing
Operation Manual
Modulator PCB is faulty.
N
Y
N
Y
N
Y
Pulse selection
function is faulty
Disconnect J2 from the
Modulator PCB. Is the fault
removed?
+250 V line is shorted
N
Modulator PCB is faulty.
Y
N
Y
Modulator PCB is faulty.
Is the TX drive signal on
TP2 (Modulator PCB)
normal?
Is +24V present on J1-1
pin(Modulator PCB) normal?
Internal wiring in the Antenna
unit or Display unit is faulty.
Antenna does not rotate
Replace the fuse
with new one.
Finished
Is the fault corrected?
N
Y
N
Motor is faulty.
Disconnect P4(J4) from the
Modulator PCB. Is the fault
removed?
Can the antenna be rotated
manually?
Check if the following conditions
are observed:
1) The antenna gets caught
with a rope.
2) Turning gear mechanism
gets stuck.
Is the Motor Fuse F2 normal (not blown)?
Pulse length A(ns) B(ms)
SP 100
0.5
M1
200
0.67 or 0.77
M2
550
1 or 1.25
LP
1050 2 or 2.5
B
5 V
0 V
A
Waveform on TP2
○
1
Internal wiring in the Antenna
unit or Display unit is faulty.
Internal wirings in the
Antenna unit or Power
Supply in the Display unit is
faulty.
8-14
93142112-00