Chapter 6
CVS-833/833C
Using the Menu
6.11.9 EXIT (Exiting from Initial Menu)
Open the “9 Exit” menu to exit from the menu by selecting one of the following exit mode menus.
6.11.9.1
EXIT with current settings
Exiting the menu without affecting the current settings in the menu. In an ordinary operation this mode
is used.
6.11.9.2 EXIT with SIMULATOR MODE
When you use this EXIT mode, the simulated picture will be displayed after exiting this menu. To finish
the simulated picture, simply turn off the sounder and then turn on again for further use.
Note: In simulated picture, the STC, Gain and the draft setting are not available.
MENU : Exit
: Sel.
: Execute
EXIT with SIMULATOR MODE
EXIT with INITIALIZE
EXIT with current settings
9 Exit
CVS-833
[KM-E05]
SELF CHECK RAM CHECK
Depth Unit Feet
50kHz/200kHz
Figure 6.31 EXIT menu display
6.11.9.3 EXIT with INITIALIZE
When you exit from the menu using this mode, the sounder settings will be defaulted.
To return to normal display, press the MENU key.
CAUTION:
Record all settings, if required, before using this mode.
CAUTION:
Whenever the internal battery is replaced, use the “EXIT with INITIALIZE”
6-22
93132902-00