background image

14

A-61626 January 2010 

Preview area

The preview area displays a sample image that is based on your 
current shortcut settings. An image will be displayed in this area after a 
preview scan has been performed.

Outline

: If you choose 

Document: Manually Select

 or 

Image: Part 

of a document

 on the Size tab, the preview area will also show the 

current outline selections. If the outline does not align with your 
preview image, you may use the mouse to adjust the size and 
location of the outline. As the mouse cursor moves around the 
outline, the cursor will change indicating that you can adjust the 
outline by pressing and holding the left mouse button.

-

Move

: place the mouse cursor within the outline to adjust the 

location of the outline.

-

Corner

: place the mouse cursor over one of the corner graphics 

to adjust two sides at the same time.

-

Side

: place the mouse cursor over one of the side graphics to 

adjust that side.

-

Rotate

: place the mouse cursor over the rotate graphic to adjust 

the angle of the outline.

Home

 — returns you to the main Scanner window.

Device

 — displays the Device Settings window.

Preview

 — initiates a scan and places the image in the preview area. 

The image displayed is a sample based on your current shortcut 
settings.

OK/Scan

 — when selected, you will be prompted to save any unsaved 

changes.

NOTE: If this button is 

OK

, any unsaved changes will remain in effect 

for the current scan session.

Cancel

 — closes the main Scanner window without saving any 

changes.

Summary of Contents for i1210 Plus

Page 1: ......

Page 2: ...for each side of a document 34 Creating different settings for each side of a document 36 Creating a new Setting Shortcut 37 Changing Image settings 39 The Device Settings window 40 Device General tab...

Page 3: ...ge outputs used for a wide variety of input documents If none of the Setting Shortcuts meet your scanning needs you can create a customized Setting Shortcut For example you could create a setting shor...

Page 4: ...he Scan Validation Tool dialog box will be displayed Scan Validation Tool dialog box The Scan Validation Tool SVT is a diagnostic application provided by Kodak The SVT user interface allows access to...

Page 5: ...displays the full path and file name for the last stored image Setup displays the user interface for the selected driver Destination allows you to select a directory to store scanned images and their...

Page 6: ...anced settings by clicking the Advanced Image Setup icon Device Settings the Device button is located on the Image Settings window When you select Device you will have access to the General and Multif...

Page 7: ...Front captures the front side only One Sided Back captures the back side only 3 Place one or two representative documents in the input tray of the scanner NOTE When scanning one side of a document or...

Page 8: ...e closely describes your desired output or you can continue to work with the Setting Shortcut you have selected by reviewing each setting on the General Size Adjustments and Enhancements tabs and make...

Page 9: ...features that are available See the section entitled The Device Settings window for information about these features 5 Determine which features you want to use when scanning and select the appropriat...

Page 10: ...Setting Shortcuts currently set up The supplied shortcuts are Default the scanner s default settings Black and White Document Black and White Document OCR Quality Color Document Color Document OCR Qu...

Page 11: ...t tray The Two Sided and One Sided Back options are only available for duplex scanner models Save saves any changes made to the current Setting Shortcut This is only available for shortcuts you have c...

Page 12: ...Setting Shortcut From this window you can also access the Device settings and Diagnostics windows Preview initiates a scan and then displays the Image Settings window with the scanned image placed in...

Page 13: ...ludes the following tabs General Size Adjustments and Enhancements Side allows you to select which side and image to configure e g Front Back Both Color 24 bit etc All image settings will be applied t...

Page 14: ...e quality at a lower resolution High displays the most accurate representation of the actual image The image that is displayed in the preview area is a good representation of what the final image will...

Page 15: ...ft mouse button Move place the mouse cursor within the outline to adjust the location of the outline Corner place the mouse cursor over one of the corner graphics to adjust two sides at the same time...

Page 16: ...nced tab Document type allows you to select the type of content on your documents Text with Graphics the documents contain a mix of text business graphics bar graphs pie charts etc and line art Text t...

Page 17: ...compress a color grayscale image NOTE The Group 4 and JPEG options are only available for Scan as Black and White 1 bit Quality if you choose JPEG compression select one of the quality options Draft...

Page 18: ...rdless of size If a document is fed crooked it will not be straightened Manually Detect the scanner will return an image based on the area you specify with the Outline options It is suggested that you...

Page 19: ...sed paper sizes Selecting an item in this list will automatically set the size of the outline to that paper s size Custom will be displayed when the outline size does not match any sizes in the list N...

Page 20: ...een scanned none Automatic the scanner will analyze each document to determine how it was fed and will rotate the image to the proper orientation 90 180 270 degrees the amount of rotation The followin...

Page 21: ...nt sets Normal ATP allows you to determine the optimal settings to produce the desired image quality This option works best when scanning with consistent document sets You may also want to use this op...

Page 22: ...k pixel to white when it is completely surrounded by white pixels or by converting a single white pixel to black when it is completely surrounded by black pixels Majority Rule sets each pixel based on...

Page 23: ...e default is 0 Does not apply to grayscale images Green changes the amount of green in the color image The values range from 50 to 50 The default is 0 Does not apply to grayscale images Blue changes t...

Page 24: ...wo additional background colors All smooths the neutral color and up to two additional background colors to white NOTE The Apply to options are only available for Method Change to White Aggressiveness...

Page 25: ...y shaped e g double punched or those having a slight tear that could have occurred when the document was removed from a binder Checking On turns hole fill on Blank Image Detection allows you to config...

Page 26: ...olor allows you to select the color to fill the edges with none White Black All side match when turned on an equal amount will be filled in on all sides Top determines how much of the top edge will be...

Page 27: ...emove the form s lines and boxes For black and white images these settings effect the grayscale version of the document which the scanner analyzes to produce that electronic image Color select the des...

Page 28: ...re NOTE The Two Sided and One Sided Back options are only available for duplex scanner models Different settings per side by default the settings you select apply to both sides of the image Turn this...

Page 29: ...o apply to the back NOTE The Different settings per side option is only available for duplex scanner models Combine front and back images typically for a document one image is created for the front si...

Page 30: ...Images per side option the Content Settings tab will be displayed Images to Configure indicates which electronic images you need to configure NOTE This is only available if you select anything other t...

Page 31: ...ing documents that are primarily black text with small logos or contain small amounts of highlighted text or small colorful photos Medium documents requiring more color as compared with the Low option...

Page 32: ...s to be present in a document before it will be saved as either color grayscale As the value of Color Amount increases more color pixels are required Valid values are 1 to 200 Color threshold the colo...

Page 33: ...that closely describes your desired output 2 Select Settings to display the Image Settings window 3 Select the Advanced Image Setup icon on the Image Settings window to display the Advanced tab 4 Sel...

Page 34: ...de option now has two entries Both Color 24 bit and Both Black and White 1 bit 10 Select Sides Both Black and White 1 bit NOTE Make any other adjustments to the black and white image settings on the r...

Page 35: ...es your desired output 2 Select Settings to display the Image Settings window 3 Select the Advanced Image Setup icon on the Image Settings window to display the Advanced tab 4 Select Input document is...

Page 36: ...n the list 8 Select Done to return to the Image Settings window NOTE You will notice that the Side option now has two entries Both Color 24 bit and Both Black and White 1 bit 9 Select Sides Both Color...

Page 37: ...o display the Advanced tab 2 Select Input document is Two Sided 3 Turn on the Different settings per side option 4 Select Images per side One 5 Select Done to return to the Image Settings window NOTE...

Page 38: ...shortcut that most closely describes the desired image output 2 Determine if you want to capture an electronic image of the front of your document back of your document or both sides of your document...

Page 39: ...ditional changes on the rest of the tabs on the Image Settings window If you are making interactive adjustments it is recommended that you preview the image using the highest preview quality 7 Define...

Page 40: ...ant the scanner to perform when scanning 6 If you want to see the result of your options Place a representative document in the input tray of the scanner Select Preview to perform a preview scan NOTES...

Page 41: ...window Preview initiates a scan and then displays the Image Settings window with the scanned image placed in the preview area The image displayed is a sample based on your current shortcut settings OK...

Page 42: ...available if you had the flatbed accessory attached when the scanning application connected to the scanner Power Saver allows you to set the amount of time in minutes the scanner has to be inactive be...

Page 43: ...least aggressive setting and is less likely to detect labels poor quality thick or wrinkled documents as multi fed documents Medium use if your job set has varying document thicknesses or labels attac...

Page 44: ...canning leave paper in path scanning will stop immediately i e making no attempt to clear the paper path and control will return to the scanning application i e ends the job Clear any documents from t...

Page 45: ...vice to display the Device Settings window 4 Before making any adjustments browse through the tabs on the Device Settings window to get familiar with options that are available 5 For each option you w...

Page 46: ...tings window Diagnostics General tab The General tab allows you to perform a scanner test and displays the scanner time Tests Scanner similar to but more extensive than a power on self test Clicking t...

Page 47: ...46 A 61626 January 2010 Diagnostics Component tab The Component tab allows you to view the current state of individual components within the scanners e g sensors...

Page 48: ...nel NOTES All of the options on this tab apply to all Setting Shortcuts not just the currently selected Setting Shortcut and are saved immediately In order for any changes on this tab to take effect y...

Page 49: ...l displays the scanner s version information serial number attached installed accessories meters etc Operator displays the scanner s log This log can only be cleared by your support personnel Toolbar...

Page 50: ......

Reviews: