ZOK-E/-Z
Page 38
ZOK K14/0917
Menu level
Sublevel
Parameter
level
Description
Value range
Default
value
available
with
Electronics
type
available with
voltage type
type
0' Offset
Setting '0' flow to
a particular
current
4-20 mA
4 mA
Z3
external
Service
User service
Change
passwort
Changing user
password
5-digit number
(00000 =>
open access)
0 Z1,Z2,Z3
Battery,external
Factory
defaults
Reset the device
to factory settings
No / Yes
No Z1,Z2,Z3
Battery,external
Menu item
selection
Hiding function for
menu items
All menu items
from menu
level selectable
No Menu
item
Z1,Z2,Z3
Battery,external
Factory
service
Password protected - reserved for factory settings
Z1,Z2,Z3
Battery,external
Device status
Devicetype Displays
devicetype
Z1,Z2,Z3
Battery,external
Counterstat Displays
counter
reading
Z1,Z2,Z3
Battery,external
Firmwareversion Displays
Firmwareversion
Z1,Z2,Z3
Battery,external
Switching
outputs
Output 1
Function
Disabled
/Dosing low
flow
disabled Z2
external
Source
Assigning
switching output
Input A
Input A
Z2
external
Output type
Assignment
output stage type
NPN / PNP /
PP
NPN Z2
external
Switching
function
Acting direction
switching function
Normally open /
Normally
closed
N.o. Z2
external
Output 2
Function
Disabled
/Dosing high
flow
disabled Z2
external
Source
Assigning
switching output
Input A
Input A
Z2
external
Output type
Assignment
output stage type
NPN / PNP /
PP
NPN Z2
external
Switching
function
Acting direction
switching function
Normally open /
Normally
closed
N.o. Z2
external
Dosing
function
Function
Stage 1 / Stage 2
Stage 1 / Stage
2
Stage 1
Z2
external
Dosing value
Defining dosage
amount
[Dosing Unit]
01000.0 Z2
external
Dosing unit
Unit volume for
dosing value
mL, L, m
3
,
galUS, galUK,
barrel, User
L Z2
external
Count direction
Count direction of
the dosing value
during the dosing
increasing /
decreasing
increasing Z2
external
Start delay high flow (only with
function "stage 2")
Dosage amount
up to turning on
stage. 2
[Dosing Unit]
00010.0 Z2
external
Stop delay high flow (only with
function "stage 2")
Dosage amount
up to turning off
stage. 2
[Dosing Unit]
00010.0 Z2
external
Dosing value max limit
Setting dosing
limit
[Dosing Unit]
02000.0 Z2
external
Dosing correction
Dosing
correcction value
±
[Dosing Unit]
00000.0 Z2
external
Missing PulseTimeout
Alarm timeout
during dosing
[s]
2 Z2
external
Summary of Contents for ZOK-ExK
Page 19: ...ZOK E Z ZOK K14 0917 Page 19 Wiring for ZOK Zx with Supply option 0 and 6 ...
Page 20: ...ZOK E Z Page 20 ZOK K14 0917 7 5 8 DOR with voltage pulse output DOR with Hall sensor output ...
Page 32: ...ZOK E Z Page 32 ZOK K14 0917 8 2 4 Display layout in measuring mode for dossier ZOK Z2 ...
Page 57: ...ZOK E Z ZOK K14 0917 Page 57 ...
Page 59: ...ZOK E Z ZOK K14 0917 Page 59 13 Dimensions ZOK ZxK ZOK Ex Zx ZOK ZxP ZOK ZxF ...