![Kobold ZOK-ExK Operating Manual Download Page 37](http://html.mh-extra.com/html/kobold/zok-exk/zok-exk_operating-manual_1982351037.webp)
ZOK-E/-Z
ZOK K14/0917
Page 37
Menu level
Sublevel
Parameter
level
Description
Value range
Default
value
available
with
Electronics
type
available with
voltage type
Decimal count
sets the decimal
points
0-4
Z1,Z3
Battery,external
Partvolume A reset
Reset subset
counter A
Button
selection Yes /
No
-
Z1,Z2,Z3
Battery,external
Partvolume B reset
Reset subset
counter B
Z1,Z3
Battery,external
Puls-output
Pulsoutput enable
-
Enabled/
disabled
disabled
Z3
external(3
‐
wire)
Source
List selection
Selection of the
associated signal
input
According to
the ‚Input type‘
in Menu ‚Signal
Input‘
Input A
Z3
external(3
‐
wire)
Pulse volume
Input volume per
output pulse in [L]
4.3 [Volume
unit]
1.000
Z3
external(3
‐
wire)
Volume unit
Volume unit input
for pulse output
mL, L, m
3
,
galUS, galUK,
barrel, User
L
Z3
external(3
‐
wire)
Pulse width
Sets the pulse
width of pulses
1ms-20s
2ms
Z3 external(3-wire)
Switching
outputs
Output 1
Function
Disabled / Limit
function /
Window
function
Deaktiviert Z3
external(3
‐
wire)
Source Assigning
switching output
According to
the ‚Input type‘
in Menu ‚Signal
Input‘
Eingang A Z3
external(3
‐
wire)
Output type
Assignment
output stage type
NPN / PNP /
PP
NPN Z3
external(3
‐
wire)
Switching
function
Acting direction
switching function
Normally open /
Normally
closed
N.o. Z3
external(3
‐
wire)
Switching
threshold
Switching
threshold
5.1 [Unit]
00035.0 Z3
external(3
‐
wire)
Lower
threshold
Threshold point
low
5.1 [Unit]
00010.0 Z3
external(3
‐
wire)
Hysteresis Switching
hysteresis
5.1 [Unit]
00001.0 Z3
external(3
‐
wire)
Suppresion
factor
Switching delay
factor
0 – 60
[x Refresh]
0 Z3
external(3
‐
wire)
Output 2
Function
Disabled / Limit
function /
Window
function
Deaktiviert Z3
external(3
‐
wire)
Source Assigning
switching output
According to
the ‚Input type‘
in Menu ‚Signal
Input‘
Eingang A Z3
external(3
‐
wire)
Output type
Assignment
output stage type
NPN / PNP /
PP
NPN Z3
external(3
‐
wire)
Switching
function
Acting direction
switching function
Normally open /
Normally
closed
N.o. Z3
external(3
‐
wire)
Switching
threshold
Switching
threshold
[Unit]
00035.0 Z3
external(3
‐
wire)
Lower
threshold
Threshold point
low
[Unit]
00010.0 Z3
external(3
‐
wire)
Hysteresis Switching
hysteresis
[Unit]
00001.0 Z3
external(3
‐
wire)
Suppresion
factor
Switching delay
factor
0 – 60
[x Refresh]
0 Z3
external(3
‐
wire)
Analogue
output
Flowrate for 20 mA
-
[Unit]
00100.000 Z3
external
Wiring type
Establishing
external circuit
2-wire / 3-wire
3-wire
Z3
external
Summary of Contents for ZOK-ExK
Page 19: ...ZOK E Z ZOK K14 0917 Page 19 Wiring for ZOK Zx with Supply option 0 and 6 ...
Page 20: ...ZOK E Z Page 20 ZOK K14 0917 7 5 8 DOR with voltage pulse output DOR with Hall sensor output ...
Page 32: ...ZOK E Z Page 32 ZOK K14 0917 8 2 4 Display layout in measuring mode for dossier ZOK Z2 ...
Page 57: ...ZOK E Z ZOK K14 0917 Page 57 ...
Page 59: ...ZOK E Z ZOK K14 0917 Page 59 13 Dimensions ZOK ZxK ZOK Ex Zx ZOK ZxP ZOK ZxF ...