9.4 Measurement Optimisation
P20: - - - a Damping
This parameter can be used to reduce unwanted fluctuation of the display and output.
a
Damping
time
(second
s)
LIQUIDS
None/moderate
fume or waves
Heavy/dense
fume or
turbulent waves
0
no filter
1
3 applicable
not
recommended
2
6 recommended applicable
3
10 recommended recommended
4
30 recommended recommended
5
60 recommended recommended
FACTORY DEFAULT: 60 sec
P22: - - - a Dome top tank compensation
This parameter can be used to reduce disturbing effect of possible multiple echos.
a
Compensation
Applied
0
OFF
In case the NUS-4 is not mounted in the centre of the top and the top is
flat.
1
ON
In case the NUS-4 is mounted in the centre of a tank with dome-shaped
top
FACTORY DEFAULT: 0
P24: - - - a Target tracking speed
In this parameter evaluation can be speed up at the expense of the accuracy.
a
Tracking speed
Remark
0
Standard
For most applications
1
Fast
For fast changing level
2
Special
Only for special applications (measuring range is reduced to 50% of the
nominal value)
The measuring window is inactive and the NUS-4 will respond practically
instantly to any target. Recommended to fast target tracking, but usually not
applicable for level metering.
FACTORY DEFAULT: 0