![Kobold HND-P210 Operating Instructions Manual Download Page 14](http://html1.mh-extra.com/html/kobold/hnd-p210/hnd-p210_operating-instructions-manual_1982445014.webp)
HND-P210
page 14
HND-P210 K08/0422
8.7 The Serial Interface
By means of the serial interface and a suitable electrically isolated interface
adapter (HND-Z031/-032) the device can be connected to a computer for data
transfer. To avoid transmission errors, there are several security checks
implemented e.g. CRC.
The following standard software packages are available:
HND-Z034
: Operation and read out of logger function, data display in
diagrams and tables
BUS-SW9M
: 9-channel software to display the measuring values
The device has 3 channels:
1: current measuring value (base address)
2: min peak (see chapter
8.6 Operation Of Logger
)
3: max peak ( see chapter
8.6 Operation Of Logger
)
Note: The measuring-/ alarm- and display range values read back from
the interface are always in the selected measurement unit (mbar, bar...)!
Supported functions:
Channel
Code
Name/Function
Channel
Code
Name/Function
1
2, 3
1
2, 3
x
x
0
Read measurement value
x
208
Read # of channels
x
x
3
Read system state
x
222
Read power off time (Conf-P.oFF)
x
12
Read ID number
x
223
Set power off time (Conf-P.oFF)
x
22
Read min alarm rail (AL. - AL.Lo)
x
x
224
Logger: Read data of CYCL- Logger
x
23
Read max alarm rail (AL. - AL.Hi)
x
225
Logger: Read cycle time (LoGG -
CYCL)
x
32
Read configuration flag
BitAlarmOn:1; BitAlarmSound:3;
BitLoggerOn:50; BitCyclicLogger:51;
BitLowPowerLogger:52
x
226
Logger: set cycle time (LoGG -
CYCL)
x
160
Set configuration flag (refer to 32)
x
227
Logger: start recording
x
x
176
Read min measuring range
x
228
Logger: Read # of recordings made
x
x
177
Read max measuring range
x
229
Logger: Read state
x
x
178
Read measuring range – measuring
unit
x
231
Logger: Read stop time
x
x
179
Read measuring range – decimal
point
x
233
Read real time clock (CLOC)
x
x
180
Read kind of measuring of sensor
x
234
Set real time clock (CLOC)
x
236
Read logger memory size
x
x
199
Read kind of measuring of display
x
237
Read logger filecount
x
x
200
Read min display range
x
238
Read logger filepointer
x
x
201
Read max display range
x
239
Read logger file info
x
x
202
Read display range - unit
x
240
Reset
x
x
204
Read display range – decimal point
x
254
Program version
x
260
Logger: read data of STOR Logger
x
x
263
Read logger channel info