H0/HA electronics options:
Supply voltage:
8 to 30 V
DC
(Hall reed switch
Supply current:
max. 5 mA (without load)
pulse output)
Hall pulse output:
active push-pull, max.
100 mA, short-circuit-
proof
HIGH level:
Min. +Vs – 1.3 V
LOW level: max. 1.3 V
Reed switch pulse output:
max. switching voltage:
30 V
DC
max. switching current:
20 mA
max. switching capacity: 0,6 W
Electronics options Z1… Z5: see operating instructions ZOK-
Electronics options 1A… 5A: see operating instructions supplement ZOK-Ex
Maximum Pressure (threaded version)
DON-H05...-20: 400 bar
Max. Flowrate Multiplier
(for higher viscosities)
Viscosities
(cP)
Standard rotor
Special cut rotor
≤ 1000
1
1
≤ 2000
0,5
1
≤ 4000
0,42
0,84
≤ 6000
0,33
0,66
≤ 8000
0,25
0,5
≤ 30000
0,15
0,3
≤ 60000
0,12
0,25
≤ 150000
0,1
0,2
≤ 250000
0,05
0,1
≤1000000
0,025
0,05
Special cut rotors for higher viscosities
For viscosity > 1000 cP, special cut rotors option „S“ should
be used to reduce pressure drop. This applies to DON-H15
and larger sizes. For higher viscosities, the flowmeter
max. flowrate is de-rated according to the attached chart.
Example: DON-H20 measuring oil at 8000 cP, max. flow
150 LPM x 0.5 = 75 LPM new maximum flow rate.
Summary of Contents for DON-05
Page 1: ...Operating Instructions for Oval Wheel Flowmeter High pressure Model DON H...
Page 9: ...DON H DON H 01 0721 page 9 Note The electronic option H0 is available with reed switch output...
Page 43: ...DON H DON H 01 0721 page 43 17 Statement of Conformity...
Page 44: ...DON H page 44 DON H 01 0721...
Page 45: ...DON H DON H 01 0721 page 45...
Page 46: ...DON H page 46 DON H 01 0721...
Page 47: ...DON H DON H 01 0721 page 47...
Page 48: ...DON H page 48 DON H 01 0721 18 State of safeness...