9.1 Disassembly of DON-H with Pulse meter
Concerning option H0/HA
9.1.1
Pulse output board removal (refer exploded view diagram
To remove the pulse output board, remove the 4 electronic cover screws (10),
and remove the electronic cover (9). The pulse output board (6) can now be
accessed and removed via the removal of the electronic board screws (7).
9.1.2
Oval gear removal for DON-H05…DON-H10 (refer exploded view
diagram
For access to the oval gears, remove the 4 lower meter body screws (5). With
care, remove the upper meter body assembly (4) being careful not to damage or
misplace the O-ring (3). You can then remove the oval gears (2).
For the small flowmeters (4 mm & 6 mm), when disassembling, please notice
the dimples located on the meter bod
y
(1 & 4) face just outside the o-ring
groove. The referencing dimples must be in alignment when reassembling. In
addition, with the small flow meters, only one oval gear is equipped with
magnets. The oval gear without magnet must be mounted on the
axle
that
is closest to the dimple. With all other devices, both oval gears are equipped
with magnets and can be mounted in a
n
y position.
5
1
2
3
4
6
7
8
9
10
2
Optional
Assembly alignment
dimple
Summary of Contents for DON-05
Page 1: ...Operating Instructions for Oval Wheel Flowmeter High pressure Model DON H...
Page 9: ...DON H DON H 01 0721 page 9 Note The electronic option H0 is available with reed switch output...
Page 43: ...DON H DON H 01 0721 page 43 17 Statement of Conformity...
Page 44: ...DON H page 44 DON H 01 0721...
Page 45: ...DON H DON H 01 0721 page 45...
Page 46: ...DON H page 46 DON H 01 0721...
Page 47: ...DON H DON H 01 0721 page 47...
Page 48: ...DON H page 48 DON H 01 0721 18 State of safeness...