background image

USER MANUAL CENTRAL HEATING STATION TYPE C15SPV24MEFM / C17SPV31MEF

 

 

9 din 17

 

Emptying the central heating station 

Emptying of the station implies the following: 
- turn off the station by pressing Power si switch off the electric power, close the gas tap; 
- close the thermal tap and the cold water input tap; 
- open the filling tap (fig.1.4), and then the consumer point of hot house water. 
 

Caution! 
Danger of hot water burns when emptying the station. 
 

9

 

Operation instructions 

9.1

 

Control Panel  

The  LMC1112  control panel (fig.1.5)  allows  the  visualization and  change of parameters  defining  the  functioning of  the  central 
heating station. It consists of: 

-

 

8 keys (J1÷J8) - tab.3 

-

 

LCD  display,  where  communication  messages  (graphic  symbols)  are  displayed.  The  meaning  of  the  10  types  of  symbols 
(S1÷S10) is presented in table 4. 

 

 
 
 
 
 
 
 

               Fig. 1.8 Functions of keys on the control panel

 

Table 3: Control panel keys 

Key 

 

Symbol

 

Description:

 

J1 

CH +

 

Used to increase the set thermal temperature or to navigate the installation submenu  

J2 

CH -

 

Used to decrease the set thermal temperature or to navigate the installation submenu 

J3 

DHW +

 

Used to increase the set temperature on hot water circuit or the value of the current parameter 
in the installation submenu  

J4 

DHW -

 

Used to decrease the set temperature on hot water circuit or the value of the current 
parameter in the installation submenu 

J5 

POWER

 

Used to switch the station on/ off  

J6 

RESET

 

Used to reset the electronic control board from an error state  

J7 

 

Used to change the functioning mode winter/ summer  

J8 

LIGHT

 

Used to activate/ deactivate the light on the display  

 
Table 4: Description of graphic symbols in the LCD display 

Tasta

 

Adnotare

 

Descriere:

 

S1 

 

It diplays the temperature (°C), set value, parameter values, informative values, various 
messages („On”, “SP”, “Co”, “EI”, “SI”, etc.) 

S2 

 

It displays informative values, parameter values, pressure 

S3 

 

It shows the state of the central heating station (Closed (OFF) = active symbol, Open (ON) = 
inactive symbol) 

S4 

 

It shows the presence of flame 

S5 

 

It shows whether the set functioning mode is SUMMER (active  symbol) 

S6 

 

It shows whether the set functioning mode is WINTER (active  symbol) 

S7 

 

The symbol is displayed continuously, which means that the station functions as thermal station. 
The symbol is displayed interrupted whenthe thermal temperature is set.  

S8 

 

If this symbol is displayed continuously it means that the station functions as hot water station. 
The symbol is displayed interrupted whenthe hot water temperature is set. 

S9 

 

It shows the fact that the S2 symbol displays the value of the pressure inside the installation 
(active  symbol)  

S10 

 

It shows the fact that there was an unsaved change of parameters in the EEPROM 
memory (it flashes) 

 

9.1

 

Description of functions and of graphic contexts diplayed on the control panel LMC1112 

9.1.1

 

LIGHT function 

 LIGHT

  k e y ( J8 fig.1.5) is used to activate/ deactivate the light on display function. 

Fig. 1.5 LMC1112 Control panel 

Fig.1.6

 

Summary of Contents for C15SPV24MEFM

Page 1: ...DURI BRANCH USER MANUAL MURAL CENTRAL HEATING STATION C15SPV24MEFM C17SPV31MEF KÖBER SRL no 25 Vaduri Alexandru cel Bun Commune Neamt 617511 Romania Tel 40 233 24 17 46 233 24 19 33 Fax 40 233 24 19 29 www motan ro ...

Page 2: ... instructions 9 9 1 Control Panel 9 9 1 Description of functions and of graphic contexts diplayed on the control panel LMC1112 9 9 1 1 LIGHT function 9 9 1 2 Graphic context station startup 10 9 1 3 Graphic context Stand by 10 9 1 4 Graphic context error state 10 9 1 5 Graphic context waiting state 10 9 1 6 Graphic context functioning state 10 9 1 7 Graphic context adjustment of functioning parame...

Page 3: ... capacities including children or by people with no experience or and no knowledge The station provides both heating in closed circuit central heating installations as well as hot water Use for other purposes or for additional purposes other than stipulated is considered inappropriate use The manufacturer is not responsible for possible damage resulting from inappropriate use The user is the only ...

Page 4: ...re on the thermal circuit 30 80 C 30 80 C Temperature on the house hot water circuit 30 55 C 30 55 C Hot water flow t 30 C 10 min 12l min Electric characteristics Input 230V 50 Hz 230V 50 Hz Nominal power EEI pump 0 2 80 W 80 W Construction characteristics Height mm 700 700 Width mm 436 436 Depth mm 303 331 Height with mounted corner 850 850 Weight 32 kg 34 5 Capacity primary heat switch 0 5 l 1 8...

Page 5: ... maximum 60 humidity between 20 30 C in order to prevent the damaging of electronic components Caution The burning air of the station must not contain substances such as flourine vapours chlorine sulphur dissolvants colorants adhesives or gasoline These substances can lead in time to the corrosion of the equipment and air gas incoming outgoing pipes Legend A Racord tur termoficare B Racord iesire ...

Page 6: ...ine ammonia alkaline agents halogenated hydrocarbs freon plaster particles lints dirt or dust Installation of the central heating station in the proximity of a swimming pool washing machine or cleaner can result in the contamination of the burning air with these compounds Water pH must be within the following limits 7 5 pH 9 5 It is recommended to check the water and thermal agent pH frequently an...

Page 7: ... an impurity filter on the return of the thermal circuit installation When installing connecting pipes it is essential for these not to be tensed to avoid creating areas of leakage Maximum working pressure allowed is 3bar Recommended working pressure is 1 5 bar Caution It is forbidden to use the central heating station without thermal agent or partilally filled danger of explosion It is forbidden ...

Page 8: ... must allow the entire electric insulataion of the central heating station for situations when interventions are required Grid connection is done taking into account the symbolism of colours as follows Brown phase Blue null Green and Yellow earthing The current plug must be accessible so that the user can easily disconnect it Caution It is not allowed to mount the central heating station with a de...

Page 9: ... Used to switch the station on off J6 RESET Used to reset the electronic control board from an error state J7 Used to change the functioning mode winter summer J8 LIGHT Used to activate deactivate the light on the display Table 4 Description of graphic symbols in the LCD display Tasta Adnotare Descriere S1 It diplays the temperature C set value parameter values informative values various messages ...

Page 10: ...s of the central heating station are active and all burning requests are accepted if no error is present In this state the display shows pressure and thermal temperature as well as the functioning mode summer winter Possible actions POWER comute between ON OFF states IN SU comute between summer winter functioning modes LIGHT activation or deactivation of light functions CH display and setting of m...

Page 11: ...emperature is lower than the limit of 60 C When the station functions with high flows the hot water temperature will be the opposite of the hot water flow but lower than the set temperature With instant WHW configuration on request the CONFORT function can be activated deactivated Please contact an authorized service company This function allows the delivery of hot water as soon as possible while ...

Page 12: ... Malfunction of flame detection Manually resettable by pressing RESET E25 YES BCU malfunction Manually resettable by pressing RESET E30 YES Malfunctioning burnt gases sensor Manually resettable by pressing RESET E31 NO Malfunctioning thermal input sensor Manually resettable by pressing RESET when the cause disappears E32 NO Malfunctioning thermal output sensor Manually resettable by pressing RESET...

Page 13: ...e 2 by which the user signs that they are aware of the correct way of using the central heating station This statement is also signed by the authorized person who commissioned the central heating station The authorised person who commissions the station has the right to refuse to sign the station commissioning statement if they notice defects of the local connecting installations and will not sign...

Page 14: ...nce over the window ventilation hole 300mm C distance left right to the window ventilation hole 300mm D E distance from the roof gutter 250mm F distance from the garage roof balcony 250mm G distance to vertical gutter 250mm H distance to internal external corners 250mm H distance to windows doors 300mm I distance to ground balcony 300mm J distance over the door 600m L distance to the door window i...

Page 15: ...et to function in four modes 4 steps Table 6 Pump functioning modes functioning mode set in the factory UPM3 Flex As m LED 1 red LED 2 yellow LED 3 yellow LED 4 yellow LED 5 yellow 4 5 6 7 To set on another curve please contact the authorized service company NOTE To save on energy and to maintain the possible functioning noises to a low level please choose a low characteristic curve P Pump pressur...

Page 16: ...put RT Central heating Input A Cold water input PC Boiler circulation pump CMC1X Boiler BCU ACM DHW domestic hot water V3C Three way valve SC Primary heating exchanger 10 4 2 Floor central heating and instant preparation of hot water This note is inform ative KÖBER Ltd don t assum es no responsibility for its proper functioning Legend TA Ambient thermostat SE Exterior temperature sensor TT Central...

Page 17: ...g exchanger BOTTOM PLAN CMC1X SE SC PC V3C RT TT TA TB TS AR A RB ACM TI PC TS Thermostat TI Thermometer TB Water tank output RB Water tank input 10 4 4 Floor central heating and accumulated preparation of hot water accummulation boiler This note is inform ative KÖ BER Ltd don t assum es no responsibility for its proper functioning Legend TA Ambient thermostat SE Exterior temperature sensor TT Cen...

Reviews: