background image

  

 

 
Version 2.000001 

 

RTB - Ready To Burn 

 

UK 

Summary of Contents for RTB

Page 1: ...Version 2 000001 RTB Ready To Burn UK ...

Page 2: ...g 5 FAQ 6 TROUBLESHOOTING 7 DANGERS AND RISKS 8 CE MARK 9 PRODUCER Dear Customer Thank you for purchasing this NBE product which is designed and manufactured to the highest standards in the EU In order for you to get the most out of your product we strongly recommend that you carefully read this manual prior to installation and operation In the event that you encounter any difficulties during inst...

Page 3: ...es prevents the pellets from moving easily and therefore increases the risk that a wood pellet bridge or mound is created along the sides of the the extraction auger opening This prevents the pellets from droping down easily into the spiral In contrast good wood pellets with minimalfines will roll down easily to the auger 1 5 Dust Moving pellets with a vacuum is naturally noisy however you can min...

Page 4: ...2 1 Technical data Wall Mount Vacuum motor Filter Cyclone Rotary Valve Controller ...

Page 5: ...C Hz 230 50 Extraction auger motor 60w Electrical Consumption ton 10kW Max Wood pellet length 35mm Max Wood pellet diameter 8mm Max wood pelet fines 1 2 2 Technical data EQUIPMENT INPUT OUTPUT CONNECTION Supply 230V PE N L Vacuum OUT1 PE N L Extraction Auger OUT2 PE N L Alarm ALARM A B Contact Cyclone IN1 1 2 Do not use IN2 3 4 Distance Sensor DISTANCE Rød Grøn Blå 2 3 Print diagram ...

Page 6: ...allation in V bottom Important Onlyuse one extraction hole in the auger 3 2 Installation Clothe Silo Put overpressure back into the top of the storage unit Put overpressure back into the top of the storage unit ...

Page 7: ...sor reading and initiating another vacuum cycle Note When USE Distance is not activated Pause Time will be ignored Start Delay Time delay before starting a vacuum cycle This delay is to ensure that there is truly a call for pellets from the capacitive sensor thus preventing overfeedingof the hopper Por After Alarm Portions Por after alarm refers to the number cycle portions the vacuum system will ...

Page 8: ...eriods during the day Sa Su The system will run until the hopper is full i e when the capacitive sensor or distance sensor registers that the hopper is full Set Clock Specify the time Set Weekday Specify the current day of the week Set Date Specify the date Set Month Specify the month Set Year Specify the year TIMING MO FR Start 1 12 05 MO FR Start 2 OFF MO FR Start 3 OFF SA SU Start 1 OFF SA SU S...

Page 9: ...eis about 500hrs 4 4 Various Language Choose language Power Auger Shows the consumption of the auger W Power Vacuum Shows the consumption of the vacuum W Distance Cal Shows calibration of the distance sensor if one is specified Consumpt Number Cycles 1950 Reset Cycles No Consumpt kWh 34 5 Reset Consumpt N0 Hours Vacuum 35 Various Language ENG Power Auger 60w Power Vacuum 650W Distance Cal 0 cm MAI...

Page 10: ...ate Vacuum Activates vacuum motor manually For example use to test function Timeout Output will automaticallyturn off after 2 minutes of running LOG 1 MON 05 34 RUN 2 MON 03 55 RUN 3 SUN 22 45 RUN 4 SUN 21 34 RUN 5 SAT 23 55 RUN 6 SAT 20 12 RUN MAIN MENU TRANSPORT TIMING CONSUMPT VARIOUS LOG MANUAL MAIN MENU TRANSPORT TIMING CONSUMPT VARIOUS LOG MANUAL ...

Page 11: ...s Normally it is not needed to clean the filter as the filter is designed only to prevent large fines from passing through but all wood pellets are different and some can cause blockages more easily than others If you are repeatedly having pressure loss in the vacuum you may want to begin a regular cleaning schedule of the filter to prevent downtime How often should you changethe vacuummotor Typic...

Page 12: ...ing time is not too long which can over fill the cyclone with pellets 4 Check that the vertical lift height is no taller than 3 5 meters 5 Check that the transport distance is no more than 15 meters 6 Check that all pipes are of the same dimension There is no power to the system 1 Make sure that there is power on the contact 2 Check to see if the fuse 7A is functional Replace if neccessary The ext...

Page 13: ...nt local rules Always disconnect the system from the power supply before starting maintenance work and servicing The system must be connected to a separate electricalcircuit which is equipped with the proper circuit breaker and residual current device Never climb into a pellet silo without proper ventilation Enough wood gas can be toxic and even deadly Always read the manual prior to installing an...

Page 14: ...Electromagnetic CompatibilityDirective 2004 108 EC Machine Directive 2009 125 CE This symbol indicated on the product confirms that the product has been produced in accordance with the above directives NBE Production A S Kjeldgaardsvej 2 9300 Sæby DENMARK 0045 88209230 www nbe dk www nbe global com 9 Producer ...