background image

• 0.1% ~ 99.9%

•NiCr-NiSi K-type sensor

Range

                                                 Accuracy

Resolution

°C

-20˜150°C                                     3°C+2

1°C

°C

150˜300°C                                    3.0% of rdg+2 digits

1°C

°C

300˜1000°C                                  3.5% of rdg+10 digits

1°C

Range

Description

Test Condition

Display reads approximate forward voltage of diode

Forward DC current 

approx. 0.4mA 

Reversed DC voltage 

approx. 1.5V

Built-in buzzer sounds if resistance is less than 90Ω

Open circuit voltage 

approx. 0.5V

Duty Cycle

Temperature

Diode and Audible Continuity Test

• Overload protection: 250V DC / 250V rms AC

SUPPLIED WITH:

1.  When the battery voltage drops below correct operational range, the “       “ symbol will appear on the 

LCD display indicating the battery needs replacing

2.  Before changing the battery, set the selector switch to OFF position and remove the test leads from 

the terminals

3. Open the cover of the battery compartment with a screwdriver
4. Replace the old battery with the same type battery (1 x 9V battery)
5. Close the cover of the battery compartment and tighten the screw

• Test leads: electric rating 1000V 20A
• “K” type thermocouple sensor probe
• Carry Case

BATTERY REPLACEMENT:

Summary of Contents for TE8

Page 1: ...79 INSTALLATION MAINTENANCE MANUAL TE8 1000A CAT III Digital Clamp Meter With Dual Display Auto power off Dual display Auto ranging CAT III Temperature function Auto backlight...

Page 2: ...nstruments with an over voltage category 1000V CAT III and Pollution Degree 2 Please follow all safety and operating instructions included in this manual to ensure the meter is used safely and is kept...

Page 3: ...test 4 RANGE button Press RANGE to select manual mode press again to change the range hold for more than 2 seconds to return to auto range mode In Hz Duty and Capacitance measurement manual mode cann...

Page 4: ...ECAUTIONS FOR OPERATION ATTENTION BEFORE OPERATION MEASURING DC VOLTAGE MEASURING AC VOLTAGE MEASURING DC CURRENT 1 Check batteries When the battery voltage drops below correct operational range symbo...

Page 5: ...Ensure the power is isolated before testing Max Input overload 250V rms 10sec 1 Connect the black test lead to COM socket and the red test lead to the V socket 5 Set the selector switch to desired CA...

Page 6: ...emperature of 250 C please note a specialist probe should be used for higher temperatures Only use the thermocouple provided or same spec model to ensure accuracy Do not import the voltage in the temp...

Page 7: ...pedance 10 M more than 100 M on 400mV range AC Voltage Range Accuracy Resolution 400mV 0 8 of rdg 5 digits 0 1mV 4V 1 0 of rdg 5 digits 1mV 40V 1 0 of rdg 5 digits 10mV 400V 1 0 of rdg 5 digits 100mV...

Page 8: ...0 digits 0 1A 50 60Hz 1000A 0 800 3 5 of rdg 10 digits 1A 50 60Hz 1000A 800 1000 6 5 of rdg 10 digits 1A 50 60Hz Range Accuracy Resolution 40nF 6 0 of rdg 10 digits 10pF 400nF 3 5 of rdg 5 digits 100p...

Page 9: ...Continuity Test Overload protection 250V DC 250V rms AC SUPPLIED WITH 1 When the battery voltage drops below correct operational range the symbol will appear on the LCD display indicating the battery...

Page 10: ...for long periods of time This product has a warranty of 1 year from date of purchase Improper use or removal of the batch codes will invalidate the warranty If this product should fail within its warr...

Reviews: