background image

• Average sensing, calibrated to rms of sinewave
• Overload protection: 1000A rms within 60 seconds

AC Current

• Overload protection: 250V DC / 250V rms AC

• Overload protection: 250V DC / 250V rms AC

• Overload protection: 250V DC / 250V rms AC

Range

Accuracy

Resolution

400Ω

1.5% of rdg+15 digits

0.1Ω

4kΩ

1.2% of rdg+15 digits

40kΩ

1.2% of rdg+15 digits

10Ω

400kΩ

1.2% of rdg+15 digits

100Ω

4MΩ

1.2% of rdg+15 digits

1kΩ

40MΩ

2.5% of rdg+15 digits

10kΩ

Range

Accuracy

Resolution

Frequency

400A

3.0% of rdg+10 digits

0.1A

50-60Hz

 1000A  0~800

3.5% of rdg+10 digits

1A

50-60Hz

1000A  800~1000

6.5% of rdg+10 digits

1A

50-60Hz

Range

Accuracy

Resolution

40nF

6.0% of rdg+10 digits

10pF

400nF

3.5% of rdg+5 digits

100pF

4μF

3.5% of rdg+5 digits

1nF

40μF

3.5% of rdg+5 digits

10nF

100μF

6.0% of rdg+10 digits

100nF

Resistance

Capacitance

Frequency

Range

Accuracy

Resolution

10Hz

1.2% of rdg+10 digits

0.01Hz

100Hz

1.2% of rdg+10 digits

0.1Hz

1000Hz

0.8% of rdg+5 digits

1Hz

10kHz

0.8% of rdg+5 digits

10Hz

100kHz

0.8% of rdg+5 digits

100Hz

1000kHz

0.8% of rdg+5 digits

1kHz

10MHz

2.0% of rdg+10 digits

10kHz

Frequency

Range of input volt-

age:1.5V~1

0V, If input

voltage over range, 

adjustment is required

Summary of Contents for TE8

Page 1: ...79 INSTALLATION MAINTENANCE MANUAL TE8 1000A CAT III Digital Clamp Meter With Dual Display Auto power off Dual display Auto ranging CAT III Temperature function Auto backlight...

Page 2: ...nstruments with an over voltage category 1000V CAT III and Pollution Degree 2 Please follow all safety and operating instructions included in this manual to ensure the meter is used safely and is kept...

Page 3: ...test 4 RANGE button Press RANGE to select manual mode press again to change the range hold for more than 2 seconds to return to auto range mode In Hz Duty and Capacitance measurement manual mode cann...

Page 4: ...ECAUTIONS FOR OPERATION ATTENTION BEFORE OPERATION MEASURING DC VOLTAGE MEASURING AC VOLTAGE MEASURING DC CURRENT 1 Check batteries When the battery voltage drops below correct operational range symbo...

Page 5: ...Ensure the power is isolated before testing Max Input overload 250V rms 10sec 1 Connect the black test lead to COM socket and the red test lead to the V socket 5 Set the selector switch to desired CA...

Page 6: ...emperature of 250 C please note a specialist probe should be used for higher temperatures Only use the thermocouple provided or same spec model to ensure accuracy Do not import the voltage in the temp...

Page 7: ...pedance 10 M more than 100 M on 400mV range AC Voltage Range Accuracy Resolution 400mV 0 8 of rdg 5 digits 0 1mV 4V 1 0 of rdg 5 digits 1mV 40V 1 0 of rdg 5 digits 10mV 400V 1 0 of rdg 5 digits 100mV...

Page 8: ...0 digits 0 1A 50 60Hz 1000A 0 800 3 5 of rdg 10 digits 1A 50 60Hz 1000A 800 1000 6 5 of rdg 10 digits 1A 50 60Hz Range Accuracy Resolution 40nF 6 0 of rdg 10 digits 10pF 400nF 3 5 of rdg 5 digits 100p...

Page 9: ...Continuity Test Overload protection 250V DC 250V rms AC SUPPLIED WITH 1 When the battery voltage drops below correct operational range the symbol will appear on the LCD display indicating the battery...

Page 10: ...for long periods of time This product has a warranty of 1 year from date of purchase Improper use or removal of the batch codes will invalidate the warranty If this product should fail within its warr...