• Connect the battery to the inverter via the connector
• Fix the T8 holders into place at either end of the fitting and attach the top cover screws
• Fit an appropriate T8 tube by locating the pins into the lamp holders and rotating 90 degrees
• Switch on power supply and check for correct operation
• The end cap can be drilled out (20mm drill bit) and a 20mm compression gland (not included) can
be used (see Fig 3) to gain access to the terminal connector
• Wire the mains cable as shown in Fig 2
• Switch on power supply and check for correct operation
3
Fig 3 End cap
ALTERNATIVE POWER SUPPLY METHOD
•
The end cap can be drilled out (20mm drill bit) and a 20mm compression gland (not included) can be used
(see Fig 4) to gain access to the terminal connector
Fig 4 End cap
•
Wire the mains cable as shown in Fig 3
•
Switch on power supply and check for correct operation
WARNING
This product must be disconnected from the circuit if subjected to any high voltage or insulation resistance testing.
Irreparable damage will occur if this instruction is not followed
GENERAL
The unit should be recycled in the correct manner when it reaches the end of its life. Check local authorities for where
facilities exist
Clean with a soft dry cloth only, do not use aggressive cleaning products or solvents which may damage the fitting
WARRANTY
This product has a warranty of 1 year from date of purchase. Failure to install this product in accordance with the current
edition of the IEE Wiring Regulations, improper use, or removal of the batch codes will invalidate the warranty. If this
product should fail within its warranty period it should be returned to the place of purchase for a free of charge
replacement. ML Accessories does not accept responsibility for any installation costs associated with the replacement
product. Your statutory rights are not affected. ML Accessories reserve the right to alter product specification without prior
notice.
20mm drill bit required
to cut out a hole for
the compression gland
Single
Twin
ALTERNATIVE POWER SUPPLY METHOD
•
The end cap can be drilled out (20mm drill bit) and a 20mm compression gland (not included) can be used
(see Fig 4) to gain access to the terminal connector
Fig 4 End cap
•
Wire the mains cable as shown in Fig 3
•
Switch on power supply and check for correct operation
WARNING
This product must be disconnected from the circuit if subjected to any high voltage or insulation resistance testing.
Irreparable damage will occur if this instruction is not followed
GENERAL
The unit should be recycled in the correct manner when it reaches the end of its life. Check local authorities for where
facilities exist
Clean with a soft dry cloth only, do not use aggressive cleaning products or solvents which may damage the fitting
WARRANTY
This product has a warranty of 1 year from date of purchase. Failure to install this product in accordance with the current
edition of the IEE Wiring Regulations, improper use, or removal of the batch codes will invalidate the warranty. If this
product should fail within its warranty period it should be returned to the place of purchase for a free of charge
replacement. ML Accessories does not accept responsibility for any installation costs associated with the replacement
product. Your statutory rights are not affected. ML Accessories reserve the right to alter product specification without prior
notice.
20mm drill bit required
to cut out a hole for
the compression gland
Single
Twin
ALTERNATIVE POWER SUPPLY METHOD
GENERAL
WARNING
WARRANTY
The product should be recycled in the correct manner when it reaches the end of its life. Check local
authorities for where facilities exist
Clean with a soft dry cloth only, do not use aggressive cleaning products or solvents which may
damage the product
This product must be disconnected from the circuit if subjected to any high voltage or insulation
resistance testing. Irreparable damage will occur if this instruction is not followed
This product has a warranty of 1 year from date of purchase. Failure to install in accordance with
the current edition of the IEE Wiring Regulations, improper use, or removal of the batch codes will
invalidate the warranty. If this product should fail within its warranty period it should be returned to
the place of purchase for a free of charge replacement. ML Accessories does not accept responsibility
for any installation costs associated with the replacement product. Your statutory rights are not
affected. ML Accessories reserve the right to alter product specification without prior notice.