background image

2

These instructions should be read carefully and retained after installation by the end user for 
future reference and maintenance.
These instructions should be used to aid installation of the following products:
T8136EMHF/T8158EMHF/T8170EMHF/T8236EMHF/T8258EMHF/T8270EMHF

GENERAL INSTRUCTIONS

SAFETY

INSTALLATION

•  Installation of this luminaire should only be carried out by a qualified electrician or competent 

person to the current Building and IEE Wiring Regulations (BS7671)

• Please isolate mains prior to installation/maintenance
•  Check the total load on the circuit (including when this luminaire is fitted) does not exceed the 

rating of the circuit cable, fuse or circuit breaker

•  Please note the IP (Ingress of Protection) rating of this luminaire when deciding the location for 

installation

• This product is Class I and requires an earth
• This product is IP20 rated

• Provide power to the point of installation
• Remove the two screws on top of the fitting (see Fig 1)

• Remove the cover plate
•  Mark the location of the fixing holes and drill the holes ensuring not to infringe with any joists, gas/

water pipes or electrical cable

• Bring the power cable into the luminaire
• Secure luminaire to the surface
•  For switched maintained operation connect the Permanent Live (brown), Neutral (blue), Earth 

(yellow and green) and Switched Live via the terminal connector (see Fig 2)

Fig 1 (single fitting shown)

Fig 2

T8XXXHF series 

These instructions should be read carefully and retained after installation by the end user for future reference and 

maintenance. 

These instructions should be used to aid installation of the following products: 

T8118HF/T8136HF/T8158HF/T8170HF/T8218HF/T8236HF/T8258HF/T8270HF 

 

SAFETY 

 

Installation of this luminaire should only be carried out by a qualified electrician or competent person to the 

current Building and IEE Wiring Regulations (BS7671) 

 

Please isolate mains prior to installation/maintenance 

 

Check the total load on the circuit, including when this luminaire is fitted, does not exceed the rating of the 

circuit cable, fuse or circuit breaker 

 

Please note the IP (Ingress of Protection) rating of this luminaire when deciding the location for installation 

 

This product is Class I and requires an earth 

 

This product is IP20 rated 

 

INSTALLATION 

 

Provide power to the point of installation

 

 

Remove two screws on top of the fitting (see Fig 1) 

 

 

Fig 1 (single fitting shown) 

 

Remove the cover plate 

 

Mark the location of the fixing holes and drill the holes ensuring not to infringe with any joists, gas/water pipes or 

electrical cable 

 

Bring the power cable into the luminaire 

 

Secure luminaire to the surface 

 

Connect the Live (brown), Neutral (blue) and Earth (yellow and green) via the three-way terminal connector (see 

Fig 3) 

 

 

 

 

 

 

 

Fig 3 

 

 

Fix the T8 holders into place at either end of the fitting and attach the top cover screws  

 

Fit an appropriate T8 tube by locating the pins into the lamp holders and rotating 90 degrees 

 

Switch on power supply and check for correct operation 

 

Remove screws 

Neutral (Blue) 

Live (Brown) 

Earth (Green/Yellow) 

T8XXXEMHF series 

These instructions should be read carefully and retained after installation by the end user for future reference and 

maintenance. 

These instructions should be used to aid installation of the following products: 

T8136EMHF/T8158EMHF/T8170EMHF/T8236EMHF/T8258EMHF/T8270EMHF 

 

SAFETY 

 

Installation of this luminaire should only be carried out by a qualified electrician or competent person to the 

current Building and IEE Wiring Regulations (BS7671) 

 

Please isolate mains prior to installation/maintenance 

 

Check the total load on the circuit, including when this luminaire is fitted, does not exceed the rating of the 

circuit cable, fuse or circuit breaker 

 

Please note the IP (Ingress of Protection) rating of this luminaire when deciding the location for installation 

 

This product is Class I and requires an earth 

 

This product is IP20 rated 

 

INSTALLATION 

 

Provide power to the point of installation

 

 

Remove two screws on top of the fitting (see Fig 1) 

 

 

Fig 1 (single fitting shown) 

 

Remove the cover plate 

 

Mark the location of the fixing holes and drill the holes ensuring not to infringe with any joists, gas/water pipes or 

electrical cable 

 

Bring the power cable into the luminaire 

 

Secure luminaire to the surface 

 

For switched maintained operation connect the Permanent Live (brown), Neutral (blue), Earth (yellow and green) 

and Switched Live via the terminal connector (see Fig 3) 

 

 

 

Fig 3 

 

Connect the battery to the inverter via the connector 

 

Fix the T8 holders into place at either end of the fitting and attach the top cover screws 

 

Fit an appropriate T8 tube by locating the pins into the lamp holders and rotating 90 degrees 

 

Switch on power supply and check for correct operation 

Remove screws 

Reviews: