Page 12 of 16
0900934 Rev: REL (05/09)
•
Continued
*** DISPENSER ***
REPORT SETUP ROUTINES
3
This menu selection allows you to change formula names. Press
YES to invoke the command, or press NO to move on to the next
menu selection.
CHANGE FORMULA NAMES ?
PRESS: YES OR NO
NO
NO
NO
NO
YES
YES
YES
YES
Choose the formula number on the top line and press
ENTER. The current formula name will appear on the
bottom line. Move the cursor to the bottom line
(SCROLL) and use alphanumeric buttons to enter the
formula name, then press ENTER. Repeat for all
formulas. Press MENU
when finished.
FORMULA 01
FORMULA 01
This menu selection allows you to enter shift times. Press YES to
invoke the command, or press NO to move on to the next menu
selection.
WANT TO SET SHIFT TIMES ?
PRESS: YES OR NO
NO
NO
NO
NO
YES
YES
YES
YES
Use the number buttons to enter the shift start times,
then press ENTER. Time must be in military format (i.e.
13:00 = 1:00 PM) Press the MENU
button to move on
to the next menu selection.
START TIMES #1 06:00
#2 11:00 #3 17:00
This menu selection sets the operating zone. The operating zone
is the time range that formulas (batches) can be dispensed.
Formulas cannot be dispensed during any time outside the
operating zone. This feature only applies to formula dispensing
and does not apply to CIP pumps. Press YES to invoke the
command, or press NO to return to the menu heading.
SET OPERATING ZONE ?
PRESS: YES OR NO
NO
NO
NO
NO
YES
YES
YES
YES
Use the number buttons to set the start and end times of
the operating zone, then press ENTER. Time must be in
military format (i.e. 13:00 = 1:00 PM). For example, if the
operating zone is 06:00 to 15:00, then formulas can only
be dispensed between 6 am and 3 pm. Press the MENU
button to return to the menu heading.
START TIME 00:00
END TIME 24:00
REPORT SETUP ROUTINES MENU HEADING