background image

0900934 Rev: REL (05/09) 

Page 1 of 16 

ILCS Edge Jr EDP 

Programming Manual 

Summary of Contents for ILCS EDGE

Page 1: ...0900934 Rev REL 05 09 Page 1 of 16 ILCS Edge Jr EDP Programming Manual ...

Page 2: ... Warranty Information 16 Knight Locations 16 CAUTION Wear protective clothing and eyewear when dispensing chemicals or other materials Observe safety handling instructions MSDS of chemical mfrs CAUTION To avoid severe or fatal shock always disconnect main power when servicing the unit CAUTION When installing any equipment ensure that all national and local safety electrical and plumbing codes are ...

Page 3: ...34 Rev REL 05 09 Page 3 of 16 WATER FLUSH BUTTONS ALPHANUMERIC KEYPAD START BUTTON CONTROL PANEL DIAGRAM NAVIGATION KEYPAD FORMULA NUMBER DISPLAY PROGRAMMING DISPLAY PUMP PRIME EXIT ABORT BUTTON BATCH COUNT ...

Page 4: ...RESS ENTER IMPORTANT NOTES Leading zeroes on the main access code and user access code and user passwords are not required to be entered For example an access code of 010 can be typed in as 10 then press ENTER Leading zeroes on user codes for dispensing chemical are required to be entered Its recommended to clear pump volumes sum cycle report batch count and restore default settings prior to initi...

Page 5: ...process is active When the process is complete the next menu item will appear CLEARING ALL PUMP VOLUMES This menu selection is used to clear the summary and batch report memory also known as the batch tracking report Press YES to begin clearing or press NO to move on to the next menu selection without clearing NOTE This will only clear the time stamps in the basic system memory There is a separate...

Page 6: ... YES YES YES YES You are then asked if you really do want to use this command Press YES if you are sure or press NO to move on to the next menu selection without loading This message indicates that the clearing process is active factory defaults are being loaded at this point When the process is complete the next menu item will appear CLEARING SETUP PLEASE STAND BY ARE YOU SURE PRESS YES OR NO YES...

Page 7: ... linked with other dispensers while performing this step Press NO if you will not be using the optional card reader SET EXT MEM MODULE ID PRESS YES OR NO NO NO NO NO YES YES YES YES You are then asked if you really do want to use this command Press YES if you are sure or press NO to continue to the next menu selection without setting This message indicates that the ID number of the external memory...

Page 8: ...memory module in menu 1 CHANGE ID PRESS YES OR NO NO NO NO NO YES YES YES YES GO TO NEXT PAGE Use the number buttons to enter a 2 digit ID number then press ENTER Press the MENU button to move on to the next menu selection NEW ILCS EDGE JR ID 01 THEN PRESS ENTER This menu selection allows you to change the main access code Press YES to invoke the command or press NO to move on to the next menu sel...

Page 9: ... selection allows you to choose if you want all pumps in a formula to run at the same time When this selection is off all pumps in the formula will run in sequence from left to right lowest number to highest Use the number buttons to make your selection Press the MENU button to continue SIMULTANEOUS PUMPS OFF 1 OFF 2 ON This menu selection tells the system which water valves will be used This prev...

Page 10: ...CROLL and alphanumeric keypad to enter a code for the user ID number shown then ENTER Use MENU or to review or change other user codes Press RESET when finished to return to the previous screen Card reader off User codes are the first 3 digits of the 8 digit combo and are numeric entries only Card reader on User codes are all 8 digits and are numeric entries only For convenience the code can be in...

Page 11: ... This menu selection allows you to change the chemical names Press YES to invoke the command or press NO to move on to the next menu selection CHANGE CHEMICAL NAMES PRESS YES OR NO NO NO NO NO YES YES YES YES Choose pump number and press ENTER Move cursor SCROLL to set the product name and press ENTER Repeat for all pumps Press MENU when finished PUMP 01 PUMP 01 This menu selection allows you to c...

Page 12: ...e number buttons to enter the shift start times then press ENTER Time must be in military format i e 13 00 1 00 PM Press the MENU button to move on to the next menu selection START TIMES 1 06 00 2 11 00 3 17 00 This menu selection sets the operating zone The operating zone is the time range that formulas batches can be dispensed Formulas cannot be dispensed during any time outside the operating zo...

Page 13: ...d CALIBRATE PUMPS PRESS YES OR NO NO NO NO NO YES YES YES YES If you know the exact flow rate of the pump you can choose to manually enter the value instead of calibrating however it is recommended to calibrate each pump as flow rates can vary due to chemical viscosity Press YES to invoke the command or press NO to move on to the next menu selection Choose the pump number and press ENTER while the...

Page 14: ... pumps in the system including pumps 9 10 if using water in the formula programming If all pumps have been calibrated press NO to continue on to the next step CALIBRATE ANOTHER Y N P 01 000 0 OZ NO NO NO NO YES YES YES YES This selection is used to input up to 99 formulas A formula can consist of one or more chemicals with different volumes of chemical per formula Each formula can include water pu...

Page 15: ...on is pressed during operation you will then see the following message PRIMING PUMPS 1 Press the PRIME button 2 Enter your access code main or user 3 Type in the pump number and press PRIME to start the pump 4 Press PRIME again to stop the pump 5 Repeat steps 3 4 as needed for any other pumps you wish to prime 6 Press the MENU button to exit the pump prime function WATER ACTIVATION Water also call...

Page 16: ...ed inspection Bearings and pump seals or rubber and synthetic rubber parts such as O rings diaphragms squeeze tubing and gaskets are considered expendable and are not covered under warranty Warranty does not cover liability resulting from performance of this equipment nor the labor to replace this equipment Product abuse or misuse voids warranty FOOTNOTE The information and specifications included...

Reviews: