0900934 Rev: REL (05/09)
Page 13 of 16
•
Prime pumps
•
Calibrate pumps
•
Manually enter pump flow rates
•
Program formulas
*** DISPENSER ***
PROGRAMMING ROUTINES
4
This menu selection allows you to prime each chemical pump.
Press YES to invoke the command, or press NO to move on to
the next menu selection.
PRIME PUMPS ?
PRESS: YES OR NO
NO
NO
NO
NO
YES
YES
YES
YES
Choose the pump number you wish to prime. Press
PRIME to start and stop the pump. Repeat for as each
pump desired. Press the MENU
button to move on to
the next menu selection.
PRIME PUMP 01
PUSH PRIME TO START/STOP
This menu selection allows you to calibrate the chemical pumps.
Press YES to invoke the command, or press NO to move on to
the next menu selection.
NOTE: Pumps must have a flow rate for formulas to be valid.
CALIBRATE PUMPS ?
PRESS: YES OR NO
NO
NO
NO
NO
YES
YES
YES
YES
If you know the exact flow rate of the pump, you can
choose to manually enter the value instead of calibrating,
however it is recommended to calibrate each pump as
flow rates can vary due to chemical viscosity. Press YES
to invoke the command, or press NO to move on to the
next menu selection.
Choose the pump number and press ENTER
while the blinking cursor is on the pump
number. Move the cursor to the right using
SCROLL, then set the flow rate and unit of
measure (decimal point button alternates
between gallons / ounces, or liters / milliliters)
and press ENTER. Repeat for all pumps
required. Press the MENU
button to move on
to the next menu selection.
FLOW RATES PER MINUTE
P-01 000.0 OZ
MANUALLY ENTER FLOW RATE
PRESS: YES OR NO
YES
YES
YES
YES
NO
NO
NO
NO
GO TO
NEXT
PAGE
Go to the next page (after calibration steps) for details on this
menu selection
FORMULA 01 PUMP 01
VOL 000.0 OZS
GO TO NEXT PAGE