background image

Diaphragm Pump NMS 030 

 

Safety 

KNF Micro BA306116-306115 NMS030-EN 0221 

Operating and Installation Instructions 

3.  Safety 

 

Observe the safety precautions in Chapters  
5. Installation and connection and 6. Operation. 

The pumps are built according to the generally recognized rules of 
technology and in accordance with the pertinent occupational 
safety and accident prevention regulations. Nevertheless, dangers 
may occur during their use which may lead to injuries to the user or 
others, or to damage to the pump or other property.  
Only use the pumps when they are in a good technical and proper 
working order, in accordance with their intended use, observing the 
safety advice within the Operating and Installation Instructions, at 
all times. 
Make sure that only trained and instructed personnel or specially 
trained personnel work on the pumps. This especially applies to 
assembly, connection and servicing work. 

Make sure that all personnel have read and understood the Oper-
ating and Installation Instructions, and in particular the "Safety" 
chapter. 

Always ensure adherence to all pertinent accident prevention and 
safety regulations when working on and operating the pump. 

When transferring dangerous media, observe the safety regula-
tions for handling such media. 

Always ensure adherence to all information stickers on the pumps, 
such as flow direction arrows and type plates, and keep stickers in 
legible condition. 

All replacement parts should be properly stored and disposed of in 
accordance with the applicable environmental protection regula-
tions. Observe the respective national and international regula-
tions. This especially applies to parts contaminated with toxic sub-
stances. 

Dispose of all packaging in an environmentally-appropriate 
manner. The packaging materials are recyclable. 

Dispose of end-of-life equipment in an environmentally 
friendly manner. Use appropriate waste collection systems 
for the disposal of end-of-life equipment. Used pumps con-
tain valuable recyclable materials. 

For the purposes of the Machinery Directive 2006/42/EC, pumps 
are “partly completed machinery", and are therefore to be regarded 
as not ready for use. Partly completed machinery may not be com-
missioned until such time as it has been determined that the ma-
chine in which the partly completed machinery is to be assembled 
conforms to the provisions of the Machinery Directive 2006/42/EC. 
The essential requirements of Annex I of Directive 2006/42/EC 
(general principles) are applied and observed. 

 

General Principles No. 1 

 

No. 1.1.2. / 1.1.3. / 1.3.1. / 1.3.3. / 1.3.4. / 1.4.1. / 1.5.8. /  
      1.5.9./ 1.7.4. / 1.7.4.1. / 1.7.4.3. 

 

Personnel 

Working in a 

safety-conscious manner 

Handling dangerous media 

Notes 

Environmental protection 

Disposal 

EU directives/standards 

Summary of Contents for NMS 030 KPDC

Page 1: ...observe at all times the relevant instructions to avoid dangerous situations The manual was produced for the serial pumps stated above With customer specified projects pump types starting with PJM or...

Page 2: ...ential danger It also indicates the possible consequences of fail ure to observe the warning The signal word e g Warning indicates the level of danger Here you will see actions for avoiding the dan ge...

Page 3: ...he pump head pump housing diaphragm and valves with the me dium The temperature of the medium must lie within the permissible temperature range see Chapter 4 The transferred gas should not contain par...

Page 4: ...Always ensure adherence to all information stickers on the pumps such as flow direction arrows and type plates and keep stickers in legible condition All replacement parts should be properly stored an...

Page 5: ...y requirements regarding electro magnetic compatibility in Directive 2014 30 EU if the pump is pow ered by an industrially produced power supply which is used within the specified limits Supply voltag...

Page 6: ...at atm Pressure l min 2 3 11 Max operating permissible pressure bar g 0 2 Max vacuum mbar abs 200 Tab 5 The pump type NMS030K_DCB brushless stands for Motor voltage 12V 24V 12V 4 24V 4 Supply voltage...

Page 7: ...put Vctrl Control voltage range DC 0 7 VDC Speed range 300 2800 1 min Resistant to surge voltages up to 28 VDC Input resistance Vctrl 5 3VDC 62 k Threshold voltage 0 11 VDC Speed voltage constants 460...

Page 8: ...Risk of physical injury and damage to the pump due to automatic start If the pump overheats and the thermal switch electronics stops pump operation the pumps will restart automatically as soon as the...

Page 9: ...designed to handle the pneumatic data of the pump see Chapter 4 Tech nical data Only use hoses that are suitable for the maximum operating pressure of the pump see Chapter 4 Only use hoses that are c...

Page 10: ...angers thereof can be prevented by placing a bypass line with a pressure relief valve between the pressure and suction side of the pump Please contact your local KNF partner for further information ww...

Page 11: ...hort cycles in your application please contact a KNF pump specialist for further information Telephone number see first page Turning the pump on In order to guarantee that the pump can start every tim...

Page 12: ...ng interval Pump Regular inspection for external damage or leaks Tab 9 7 2 Cleaning 7 2 1 Cleaning the pump The pump if necessary clean outside with a dry wipe Do not use cleaning solvents as these ma...

Page 13: ...the suction and pressure sides such as hoses valves or filters are causing too much resistance Modify installation check the cross sections of components Hose connections are not leak tight Secure tra...

Page 14: ...ump see the Chapter Cleaning the pump 4 Send the pump together with completed Health and Safety Clear ance and Decontamination Form to KNF stating the nature of the transferred medium 5 Package the de...

Page 15: ...Diaphragm Pump NMS 030 Returns KNF Micro BA306116 306115 NMS030 EN 0221 Operating and Installation Instructions 15 KNF worldwide Find our local KNF partner on www knf com...

Page 16: ...Diaphragm Pump NMS 030 Revisionsbeschreibung KNF Micro BA306116 306115 NMS030 EN 0221 Original Betriebs und Montageanleitung...

Reviews: