background image

Diaphragm Pump NMS 030 

 

Safety 

KNF Micro BA306116-306115 NMS030-EN 0221 

Operating and Installation Instructions 

As these partly completed machinery are OEM-models the power 
supplies and the equipment for disconnecting and switching-off the 
partly completed machinery respectively have to be considered 
when mounting as well as over-current and overload protective 
gear. 

In addition a protection against mechanical parts in motion, hot 
parts, if existing, has to be provided when mounting. 

The pumps comply with the safety requirements regarding electro-
magnetic compatibility in Directive 2014/30/EU, if the pump is pow-
ered by an industrially produced power supply which is used within 
the specified limits. (Supply voltage motor current, load torque). 

The pumps comply with the fundamental requirements of Directive 
2011/65/EU (RoHS2). 

The following harmonised standards are met:: 

NMS 030 K_DC 

NMS 030 K_DCB 

 

DIN EN 55014-1 

DIN EN 55014-1 

1)

 

 

DIN EN 55014-2 

DIN EN 55014-2 

 

DIN EN 60034-1 

DIN EN 61000-6-1 

 

DIN EN 61000-6-1 

DIN EN 61000-6-3 

 

DIN EN 61000-6-2 

 

 

Tab. 2 

1)

 see chapter 5.2 

All repairs to the pump(s) must be carried out by the relevant KNF 
customer service team.  
Only use genuine parts from KNF for servicing work. 

 

Customer service and repairs 

Summary of Contents for NMS 030 KPDC

Page 1: ...observe at all times the relevant instructions to avoid dangerous situations The manual was produced for the serial pumps stated above With customer specified projects pump types starting with PJM or...

Page 2: ...ential danger It also indicates the possible consequences of fail ure to observe the warning The signal word e g Warning indicates the level of danger Here you will see actions for avoiding the dan ge...

Page 3: ...he pump head pump housing diaphragm and valves with the me dium The temperature of the medium must lie within the permissible temperature range see Chapter 4 The transferred gas should not contain par...

Page 4: ...Always ensure adherence to all information stickers on the pumps such as flow direction arrows and type plates and keep stickers in legible condition All replacement parts should be properly stored an...

Page 5: ...y requirements regarding electro magnetic compatibility in Directive 2014 30 EU if the pump is pow ered by an industrially produced power supply which is used within the specified limits Supply voltag...

Page 6: ...at atm Pressure l min 2 3 11 Max operating permissible pressure bar g 0 2 Max vacuum mbar abs 200 Tab 5 The pump type NMS030K_DCB brushless stands for Motor voltage 12V 24V 12V 4 24V 4 Supply voltage...

Page 7: ...put Vctrl Control voltage range DC 0 7 VDC Speed range 300 2800 1 min Resistant to surge voltages up to 28 VDC Input resistance Vctrl 5 3VDC 62 k Threshold voltage 0 11 VDC Speed voltage constants 460...

Page 8: ...Risk of physical injury and damage to the pump due to automatic start If the pump overheats and the thermal switch electronics stops pump operation the pumps will restart automatically as soon as the...

Page 9: ...designed to handle the pneumatic data of the pump see Chapter 4 Tech nical data Only use hoses that are suitable for the maximum operating pressure of the pump see Chapter 4 Only use hoses that are c...

Page 10: ...angers thereof can be prevented by placing a bypass line with a pressure relief valve between the pressure and suction side of the pump Please contact your local KNF partner for further information ww...

Page 11: ...hort cycles in your application please contact a KNF pump specialist for further information Telephone number see first page Turning the pump on In order to guarantee that the pump can start every tim...

Page 12: ...ng interval Pump Regular inspection for external damage or leaks Tab 9 7 2 Cleaning 7 2 1 Cleaning the pump The pump if necessary clean outside with a dry wipe Do not use cleaning solvents as these ma...

Page 13: ...the suction and pressure sides such as hoses valves or filters are causing too much resistance Modify installation check the cross sections of components Hose connections are not leak tight Secure tra...

Page 14: ...ump see the Chapter Cleaning the pump 4 Send the pump together with completed Health and Safety Clear ance and Decontamination Form to KNF stating the nature of the transferred medium 5 Package the de...

Page 15: ...Diaphragm Pump NMS 030 Returns KNF Micro BA306116 306115 NMS030 EN 0221 Operating and Installation Instructions 15 KNF worldwide Find our local KNF partner on www knf com...

Page 16: ...Diaphragm Pump NMS 030 Revisionsbeschreibung KNF Micro BA306116 306115 NMS030 EN 0221 Original Betriebs und Montageanleitung...

Reviews: