Installation and connection
Diaphragm Pump N1200.12, N1400.1.2.12
18
Translation of Original operating and installation instruction, English, KNF 308930-308933 02/22
6 Installation and connection
Only install the pumps in accordance with the operating parameters and
conditions described in Chapter
.
à
Observe the safety instructions (see Chapter Safety).
DANGER
Risk of dangerous gas mixtures during pump op-
eration
Depending on the medium being transferred,
breakage of the media-contacting components
can result in a dangerous mixture if the medium
mixes with the air in the compressor housing or
the surroundings.
à
Before using a medium, check the compati-
bility of the media-contacting components
(see
6.1 Installing the pump
à
Store the pump at the installation site to allow it to adapt to the ambient
temperature before installation (condensation must not be allowed to
form).
Mounting dimensions
à
For mounting dimensions, see the following figures:
Fig.6 Mounting dimensions pump series N1200.12