Diaphragm Pump N1200.12, N1400.1.2.12
Technical data
Translation of Original operating and installation instruction, English, KNF 308930-308933 02/22
11
Electrical data
N1200.12
Parameter
Value
Value
Value
Value
Voltage [V]*
200/346
277/480
220/380
230/400
Frequency [Hz]*
50/60
60
60
50
Power P
1
[W]
**
**
**
900
Current consumption [A] **
**
**
7.8/4.5
Motor protection class
See motor type plate
Max. permissible mains
voltage fluctuations
See operating instructions for motor
Tab.9 *For further voltage and frequency variants, see type plate
**See type plate
N1400.1.2.12
Parameter
Value
Value
Value
Value
Voltage [V]*
200/346
277/480
220/380
230/400
Frequency [Hz]*
50/60
60
60
50
Power P
1
[W]
**
**
**
1350
Current consumption [A] **
**
**
6.75/3.9
Motor protection class
See motor type plate
Max. permissible mains
voltage fluctuations
See operating instructions for motor
Tab.10 *For further voltage and frequency variants, see type plate
**See type plate
Weight
Pump type
Weight [kg]
N1200.12
approx. 60
N1400.1.2.12
approx. 82
Tab.11