Technical data
Diaphragm Pump N1200.12, N1400.1.2.12
12
Translation of Original operating and installation instruction, English, KNF 308930-308933 02/22
Other parameters
Parameter
Value
Permissible ambient temperature
[°C]
+ 5 to + 40
Permissible media temperature [°C] + 5 to + 40
Max. surface temperature* [°C]
+ 105
Dimensions
N1200.12
N1400.1.2.12
Fig. 6
Fig. 7
Gas tightness** of the pump head
(Leak rate):
N1200SP.12E/N1400.1.2SP.12E
< 6 x 10
-6
mbar l/s***
Highest permissible relative air hu-
midity of the environment
80% for temperatures to 31°C, de-
creasing linearly to 50% at 40°C.
Maximum installation altitude [m
above sea level]
See operating instructions for motor
Protection class of pump:
N1200.12
N1400.1.2.12
IP 00
IP 00
Tab.12 *To reduce the surface temperature of the pump heads and to extend the
service life of the diaphragm, you can optionally attach a water cooling system (see
Chapter 6.5 Connecting water cooling (optional)).
**The gas tightness of the pump head is no longer ensured after the pump head is
opened or after changing diaphragm and reed valves. A leak test can be used to
determine whether the original gas tightness is again achieved.
***Values apply for helium leak test
Additional equipment
The pump is equipped with a safety diaphragm.
à
For explanation on the task and principle, see Chapter
à
For information on installation and connection, see Chapter
.
à
For information operation, see Chapter
.
Summary of Contents for N1200.12
Page 53: ...13...
Page 55: ...15 9 Documents provided Circuit diagram...
Page 57: ......
Page 58: ......
Page 59: ......
Page 60: ...KNF worldwide You can find our local KNF partners at www knf com...