Installation and connection
Diaphragm pump N 2400.15
20
Translation of original Operating and Installation Instructions, english, KNF 308934-308937 09/18
The IP protection class of the pump motor is indicated on the
type plate.
Install the pump at the highest point in the system to prevent
condensate from collecting in the pump head.
Protect the pump from dust.
Protect the pump from vibrations and jolts.
WARNING
Personal injury and/or damage to property because
of vibration
In conjunction with adjacent components, vibration of
the pump may result in crushing and/or damage to
these components.
Make sure that vibrations of the pump do not
result in hazards associated with adjacent com-
ponents.
The pump can be installed in any position. Secure the pump
with metallic screws to the attachment points shown.
Protect the pump against contact and intrusion of foreign mat-
ter.
7.2. Electrical connection
DANGER
Extreme danger from electrical shock
Only have the pump connected by an authorized
specialist.
Only have the pump connected when the power
supply is disconnected.
When connecting the device to a power source, the relevant
standards, directives, regulations, and technical standards
must be observed.
For electrical connection, carefully read and observe the motor
operating instructions (also including information on insulation
resistance measurement).
In the electrical installation, arrangements (complying with
EN 60335-1) must be made for disconnecting the pump motor
from the electrical supply.
The motors of the pump must be protected according to
EN 60204-1 (protection against excess current, or overload-
ing).
For max. operating current of the pump see pump’s type plate.
It is recommended that an additional “Emergency Stop” switch
is installed.
The pump must be installed so that contact with live parts is
impossible.
Installation position
Foreign matter protection