Installation and initial start-up
Operating Instructions LIQUIPORT EN
26
KNF Flodos | BA_LIQUIPORT_EN_11_153820.docx | Translation of original operating instructions, English
NOTE
KNF retains the right to refuse repair of pumps that are used to move
hazardous materials.
This applies particularly to the following materials:
-
Poisons
-
Radioactive media
-
Elementary halogens (e.g. bromine)
6.
Installation and initial start-up
6.1 Safety
WARNING
Danger as a result of incorrect installation
Injuries or damage to equipment caused by escaping media
-
Follow installation instructions
-
After assembly, test the system with a harmless liquid
-
Only use pump if it is in perfect working order
WARNING
Danger of serious injuries or property damage caused by escap-
ing media in the event of rupturing of the pump diaphragm
Poisoning and caustic burns caused by escaping media as a result of
rupturing of the pump diaphragm. If the pump diaphragm ruptures, the
medium is channelled out of the pump through the discharge outlet.
-
When transferring critical media, operate the pump in a col-
lecting tank
-
Check discharge outlet for leaks
WARNING
Danger of serious injuries or property damage caused by escap-
ing media in the event of overpressure on the suction side
Overpressure on the suction side will result in uncontrolled escape of
fluid, even if the pump is not operating.
-
Avoid overpressure on the suction side
The following requirements apply to all the activities described in this
chapter:
▪
Device is in perfect working order
▪
The system is operated with water
▪
Must be assembled by specialist personnel
▪
Not required
Requirements
Personnel
Personal protective equipment