30 

 

CS.ECO-TFT.IST-1-EN / Rev 1.0

                                                                                                                                                              ENGLISH 

BOILER WIRING DIAGRAM 

TRASFORM ATORE

Terra

Fase

Neutro

RETE 230Vac

P

M

CN9

CN

13

CN

5

CN2

CN7

IMPORTANTE:

NON INVERTIRE

LA POSIZIONE

DEI FILI

Legenda DISPOSITIVI DI SICUREZZA:
ALp

= Micro chiusura porta fuoco

ALs

= Micro chiusa porta serbatoio pellet

ALf

= Pressostato fumi

ALt

= Termostato a riarmo manuale

LEGENDA COMPONENTI:
M1

= Motoriduttore coclea

M2

= Motoriduttore pulizia turbolatori

M3

= Motoriduttore pulizia braciere

(solo mod. predisposti)

C

= Candeletta di accensione

A

= Aspiratore fumi con tachimetrica

P1

= Circolatore caldaia

P2

= Circolatore riscaldamento impianto (

solo mod.

predisposti)

V1

= Valvola motorizzata a tre vie

PVS

= Motore Vacuum di carico pellet ausiliario

(predisposizione opzionale)

D1

= Display LCD principale

D2

= Display TFT principale

D3

= Display TFT remoto

 (opzionale)

LEGENDA SONDE / CONTATTI / SENSORI:
SF

= Sonda fumi "tipo termocoppia K"

SC

= Sonda h2o caldaia "tipo NTC 10K ± 1%"

SB1

= Sonda (centrale/superiore) h2o bollitore/puffer

"tipo NTC 10K ± 1%"

(predisposizione opzionale)

SB2

= Sonda (inferiore) h2o puffer

"tipo NTC 10K ± 1%"

(predisposizione opzionale)

TA

= Contatto termostato ambiente

FS

= Flussostato acqua sanitaria

(predisposizione opzionale)

FP

= Micro finecorsa pulizia braciere

(solo modelli predisposti)

SP

= Sensore di livello pellet

PC1

= Contatto consenso A caldaia a pellet DA

pompa di calore

PC2

= Contatto consenso forzato (emergenza) A

pompa di calore DA caldaia a pellet

PC3

= Contatto consenso ACS A pompa di calore

FUSIBILE

4A 5X20

CN

10

SCHEDA L023_8-128Kb

CN

1

CONNETTORE

PER

CONNESSIONE

BOOTLOADER

G

/ Y

E

W

/ R

D

BATTERIA OROLOGIO
CRONOTERMOSTATO

TIPO CR2032 3Volts

CN

17

CN

21

CN

22

 ENC   +5V  GN D    BLU

BU

BK

RD

 / 

BN

SCHEDA ESPANSIONE W055 (OPZIONALE)

CN

12

CN

4

CN

8

CN

16

CN

19

CN

6

    PELLET       H 2O            AMB         T ERM         +TC 1-

   

  AU

X2

   

   

 A

L3

   

 N

   

V2

/P0

PBC

   

  N

AUX1

RELÈ ACCENSIONE

RELÈ PBC

CN15

AUXIN

 PMP  PW M

CN23

CN

14

BK

RD

WH

SE

R

IA

LE

EN

C.

 C

O

C

.

- O

C

 +

- O

C

 +

D

IS

PL

AY

M

M

   

  SC

AM

.  

   

   

 FU

M

I  

   

   

 N

   

   

  F

   

 N

   

  AL

   

AL

   

   

 AC

C

.  

   

   

  C

O

C.

SCHEDA ESPANSIONE

W055 CONNESSA A

L023_8 CON I

CONNETTORI CN10,

CN12 E CN14

FU

N

1

FU

N

2

P

AL

f

AL

t

AL

s

Micro

Micro

RELÈ

 N

 C

o

m

  

N

o

RELÈ

 N

 C

om

  N

o

AL

p

RELÈ COCLEA

RE

CN5

COM    01      02      03

CN10

   04      05

CN

4

CN

2

CN12

CN1

 GN D 0-10C GN D 0-10V+12V

CN

6

 +

5V

     

I1  

    I

2   

   I3

    

  I4

    

 G

N

D

D2

D3

Legenda COLORI

BN

= Marrone

GN

= Verde

YE

= Giallo

WH

= Bianco

BK

= Nero

BU

= Blu

OG

= Arancione

RD

= Rosso

VT

= Viola

PK

= Rosa

GY

= Grigio

GNYE

= Verde / Giallo

Morsettiera DISPLAY REMOTO:
D3

(K-01.1 / K-01.2 / K-01-3 / K-01.4) Gestione DISPLAY TFT REMOTO

SA

opzionale (K-01.5 / K-01.6) Temperatura da SONDA AMBIENTE

Morsettiera INGRESSI
TA

(K-10.1 / K-10.2) Consenso funzionamento riscaldamento impianto da

TERMOSTATO AMBIENTE (contatto pulito)

SB1

(K-11.1 / K-11.2) Temperatura da SONDA PUFFER (centrale/superiore)

FS

(K-12.1 / K-12.2) Consenso ACS da FLUSSOSTATO (contatto pulito)

Morsettiera USCITE
V1

(K-20.1 / K-20.2 / K-20.3) Gestione a VALVOLA MOTORIZZATA A TRE VIE (230V)

(K-21.1) Massa Terra

P2

(K-22.1 / K-22.2) Consenso attivazione a CIRCOLATORE RISCALDAMENTO (230V)

Morsettiera RELE'
PC3

da (K-30.1 / COM 4_11 / NO 3_14) a (X-20.1 / X-20.2)

Consenso ACS a POMPA DI CALORE (contatto pulito)

PC2

da (K-31.1 / COM 4_11 / NC 2_12) a (X-16.1 / X-16.2)

Consenso funzionamento forzato (emergenza) a POMPA DI CALORE
da CALDAIA A PELLET (contatto pulito)

PC1

da (X-6.1 / X-6.2) a (K-32.1 / A1_5 / A2_1) Consenso funzionamento

a CALDAIA A PELLET da POMPA DI CALORE (230V)

PVS

opzionale (K-33.1 / COM 4_11 / NO 3_14) Consenso attivazione VACUUM

di carico pellet ausiliario (contatto pulito)

GND

A
B

+12V

GND

A
B

+12V

-

BN

K-01.1

VT

K-

11

.2

PVS

   F 230V

   N 230V

V1 = VALVOLA MOTORIZZATA A TRE VIE
(Gestione ACS tipo impianto 1, 2, 3)
GNYE

 = Massa terra

BN

= Lato riscaldamento (Fase 230V quando ACS non in richiesta)

BK

= Lato sanitario (Fase 230V quando ACS in richiesta)

BU

= Comune (Neutro 230V)

P1

M3

PC

1

Ca

vo

 p

er

 c

ol

le

ga

m

en

to

 ta

ch

im

et

ric

a

23

0V

Pu

lito

Pu

lito

Pu

lito

   230V

230V

Pulito

   230V

   F 230V

   230V

   230V

   230V

230V

nt

10

K

nt

10

K

K-

33

.1

NC

 2

_1

2

NO

 3

_1

4

CO

M

 4

_1

1

OG

OG

A1

_5

A2

_1

K-32.1

NC 2_12

NO 3_14

COM 4_11

BU

A1_5

A2_1

BU

VT

K-

11

.1

WH

K-

10

.2

WH

K-

10

.1

X-

6.

2

X-

6.

1

nt

10

K

Pu

lito

GN

YE

RD

K-22.2

RD

K-22.1

K-21.1

230V

BU

K-20.3

BK

K-20.2

K-21.1

K-20.1

BN

230V

V1

230V

PC3

X-20.2

X-20.1

230V

230V

Pu

lito

RE

RE

RE

SB

1

SP

 F

P

SC

 T

A

SF

M2

M1

C

A

PVS

P2

   F 230V

   N 230V

F 230V

F 230V

   230V

GN

YE

GN

YE

ntc 10K

SA

Pu

lito

OG

K-

12

.2

OG

K-

12

.1

 F

S

Pulito

K-

30

.1

NC

 2

_1

2

NO

 3

_1

4

CO

M

 4

_1

1

GN

GN

A1

_5

A2

_1

PC2

X-16.2

X-16.1

Pulito

K-

31

.1

NC

 2

_1

2

NO

 3

_1

4

CO

M

 4

_1

1

GY

GY

A1

_5

A2

_1

230V

GY

K-01.6

PK

K-01.5

ntc 10K

X-22.1 X-20.1 X-19.1 X-17.1

X-12.2 X-12.1

X-12.2 X-12.1

X-22.2 X-20.2 X-19.2 X-17.2

X-22.2 X-20.2 X-19.2 X-17.2

X-22.1 X-20.1 X-19.1 X-17.1

X-15.1

X-15.2

X-15.2

X-15.1

X-16.1

X-16.2

X-16.2

X-16.1

X-5.1

X-5.2

X-5.2

X-5.1

X-4.1

X-4.1

X-14.1 X-11.1 X-10.1

X-14.2 X-11.2 X-10.2

X-14.2 X-11.2 X-10.2

X-14.1 X-11.1 X-10.1

X-9.1

X-9.2

X-9.2

X-9.1

X-6.1

X-6.2

X-6.2

X-6.1

L

N

N

L

X-1.1

X-1.1

K-01.1 K-01.2 K-01.3 K-01.4

K-10.1 K-10.2 K-11.1 K-11.2

K-30.1

K-22.1 K-22.2

K-21.1

K-20.1 K-20.2 K-20.3

DISPLAY REMOTO

INGRESSI

W055

CN4

W055 / L023_8

CN5 / CN8

(03 - 02 / N)

L023_8

CN7

(TERM)

L023_8

CN7

(PELLET)

W055 / L023_8

CN5 / CN8

(02 / N)

W055 / L023_8

CN10 / CN8

(05 / N)

BN GN

YE WH

WH WH

VT

VT

GN

GN

RD RD

GNYE

BN

BK BU GN

YE

M

icr

o

PV

S

P2

    

 T

A

P2

V1

M

icr

o

Pu

lit

o

nt

10

K

Pu

lit

o

23

V

Pu

lit

o

23

V

23

V

COM 4_11

COM 4_11

NO 3_14

NC 2_12

A2_1

A1_5

K-33.1

OG

OG

A2_1

A1_5

NC 2_12

NO 3_14

COM 4_11

L023_8

CN8

(SCAM )

USCITE

MORSETTIERA

OPZIONALE

RELE'

SB

1

P2

PV

S

K-01.5 K-01.6

W055

CN6

(GND / I2)

PK

GY

nt

10

K

SA

SONDA

AMBIENTE

K-12.1 K-12.2

L023_8

CN7

(AMB)

OG OG

    

 F

S

Pu

lit

o

NO 3_14

NC 2_12

W055

CN6

(GND i1)

23

V

K-32.1

BU

A2_1

A1_5

NC 2_12

NO 3_14

COM 4_11

BU

K-31.1

A2_1

A1_5

W055 / L023_8

CN10 / CN8

(04 / N)

Pu

lit

o

GY

GY

nt

10

K

SB

1

1

D4

RETE

23

0V

ac

A
B

+12V

-

A
B

+12V

K-01.2

K-01.3

K-01.4

WH

GN

YE

2

3

4

5

6

7

8

12V+

12V-

GND

R-

R+

-

D3

A

B

+1

2V

PC

3

PC

2

PC

1

D1

Legenda COMPONENTI
D3

= Display TFT remoto caldaia a pellet (opzionale)

D4

= Display remoto pompa di calore

SA

= Sonda Ambiente (opzionale)

TA

= Termostato Ambiente

SB1

= Sonda h2o puffer

FS

= Flussostato acqua sanitaria

V1

= Valvola motorizzata a tre vie

P2

= Circolatore riscaldamento impianto

PVS

= Motore Vacuum di carico pellet ausiliario (opzionale)

PC1

= Consenso A caldaia a pellet DA pompa di calore

PC2

= Consenso A pompa di calore DA caldaia a pellet

PC3

= Consenso ACS A pompa di calore

MORSETTIERA CALDAIA A PELLET

MORSETTIERA POMPA DI CALORE

 

W055 EXPANSION BOARD (OPTIONAL)

 

BOARD L023_8-125 kB

 

W055 EXPANSION 

BOARD CONNECTED 

TO L023_8 WITH CN10, 

CN12 AND CN14 

CONNECTORS 

4 A 5X20 

FUSE

 

AUX1

 

TRANSFORMER

 

IGNITION RELAY

 

PBC RELAY

 

EN

C

. S

C

.F

.

 

SE

R

IA

L

 

CONNECTOR FOR 

BOOTLOADER 

CONNECTION 

PROGRAMMABLE 

THERMOSTAT CLOCK 

BATTERY (TYPE CR2032 3 

Volts)

 

IMPORTANT: DO 

NOT INVERT THE 

WIRES 

SCREW F. RELAY

 

C

ab

le

 fo

r t

ac

ho

m

et

er

 c

on

ne

ct

io

n

 

Live

 

Neutral

 

MAINS 230 

VAC 

Earth

 

RELAY

 

Dry

 

Dry

 

Dry

 

R

EL

AY

 

R

EL

AY

 

R

EL

AY

 

R

EL

AY

 

FUME

S

 

EX

C

H

.

 

SC

.F

.

 

ST

OR

.

 

Dry

 

Micro

 

Micro

 

THERM

 

Dry

 

BLUE

 

Dry

 

Dry

 

Dry

 

Dry

 

SAFETY DEVICE KEY:

 

ALp

 = Fire door closure 

micro-

switch

 

ALs

 = Pellet tank door closing 

micro-

switch 

ALf

 = 

Flue gas pressure switch

 

ALt = Manual-reset thermostat 

 
KEY TO COMPONENTS:

 

M1

 = 

Screw feeder gearmotor 

M2

 = 

Turbulator cleaning gearmotor 

M3

 = 

Brazier cleaning gearmotor 

(configured models only

)

 

C

 =

 Spark plug 

A

 

Flue gas extractor with tachometer 

P1

 = 

Boiler circulator pump 

P2

 = 

System heating circulator pump 

(

configured models only)

 

V1

 =

 Motor-driven three-way valve 

PVS

 = Auxiliary pellet loading vacuum motor 

(optional configuration)

 

D1

 = 

Main 

LCD

 

D2

 = Main TFT display 

 

KEY TO PROBES / CONTACTS / SENSORS: 

SF

 =

 

“Thermocouple type K” flue gas probe

 

SC

 

= Boiler H2O “NTC type 10K ± 1%” probe

 

SB1

 

= Water heater/puffer H2O probe (central/upper) 

“type NTC 10K ± 1%” 

(optional configuration) 

SB2

 

= Puffer H2O probe (lower) 

“type NTC 10K ± 1%” 

(optional configuration) 

TA

 = Room thermostat contact 

FS

 

= Domestic water flow switch 

(optional configuration) 

FP

 = Brazier cleaning micro limit switch 

(configured models only)

 

SP

 = Pellet level sensor 

PC1

 

= Contact for consent TO pellet-fired boiler FROM 

heat pump 

PC2

 

= Forced consent contact (emergency) TO 

heat pump FROM pellet-fired boiler 

PC3

 =

 Contact for DHW consent TO heat pump 

 

V1 = MOTOR-DRIVEN THREE-WAY VALVE

 

(DHW management in plant types 1, 2, 3)

 

GNYE

 = 

Earth 

BN

 = 

Heating side (Live 230 V when DHW not requested) 

BK

 

=

 DHW side (Live 230 V with DHW demand) 

BU

 = Common (Neutral 230 V) 

 

D

IS

PL

AY

 

PELLET
S

 

Summary of Contents for ECOMPACT 190

Page 1: ...CS ECO TFT IST 1 EN Rev 1 0 ECOMPACT 190 ECOMPACT 250 ECOMPACT 270 ECOMPACT 290 ECOMPACT 320 EN INSTRUCTIONS FOR USE...

Page 2: ...7 EXTERNAL AIR INTAKE 7 SMOKE DUCTS AND CONNECTION TO THE FLUE 7 CHIMNEY 9 ELECTRICAL CONNECTION 10 CONTROL OF A POSSIBLE THREE WAY MOTORIZED VALVE FOR DHW SYSTEM MANAGEMENT 10 CONNECTION TO THE ROOM...

Page 3: ...odifications to the appliance Do not touch the hot components of the product ceramic glass flue pipe during normal operation Never touch the appliance if you are barefoot and or if you have wet or dam...

Page 4: ...he boiler puffer sensor Yes Electrical configuration for the control of the optional automatic pellet loader Yes Remote control Optional The appliance is supplied with the following material 1 User in...

Page 5: ...ENGLISH Terminal for room thermostat connection Air intake pipe Anti interference filter connection for power supply cable with 2 built in fuses 4A 250V Expansion vessel 10 l with pre load 1 bar LEFT...

Page 6: ...100 100 100 100 100 Air intake pipe diameter mm 40 50 50 50 50 Boiler unit capacity litres 42 52 52 52 52 Pellet tank capacity kg 55 75 90 75 90 Minimum chimney draught at nominal heat output Pa 10 0...

Page 7: ...llets The use of poor quality pellets or any other material can damage the appliance operation voiding the warranty and exempting the manufacturer from all liability In order to guarantee trouble free...

Page 8: ...not obstructed thereby impeding the passage of air Therefore keep the air vents clear of obstructions The UNI 10683 Standard FORBIDS the drawing of combustion air from garages warehouses storing comb...

Page 9: ...pipes to transit inside the flue gas pipes even if they are over sized FURTHER SPECIFICATIONS TO BE CONSIDERED The appliance works with the combustion chamber in negative pressure and the flue pipe un...

Page 10: ...ensure the discharge of combustion by products even in the event of winds from every direction and inclination The outlet height where height refers to the top of the flue regardless of any chimney st...

Page 11: ...ontrolling this valve see also Wiring diagram The four wires connected to the terminal block have different colours precisely Blue wire 3 WAY VALVE COMMON Neutral 230 V Black wire DOMESTIC WATER SIDE...

Page 12: ...with the current regulations When installing the appliance it is advisable to fit an anti condensate mixer valve between the delivery and return pipes on the appliance s heating system The anti conden...

Page 13: ...te border Shows the set power White filling Shows the actual working power modulation example 7 Set room Allows for accessing the SET ROOM set point field available only if ROOM SENSOR is enabled Top...

Page 14: ...UMP appears only with sub menu INSTALLER PLANT TYPE 5 Allows for enabling disabling the operation consent for the paired heat pump OFF No consent to the heat pump Pellet based operation only ON Consen...

Page 15: ...to enable and disable the programming schedule within it OFF Any programme set within the WEEKLY TIMER is disabled ON Any programme set within the WEEKLY TIMER is enabled Press SET to access the WEEK...

Page 16: ...lows you to enable or disable the acoustic signal in the event of an alarm Sub menu 4 3 CHOOSE LANGUAGE Allows you to select the dialogue language from the available options Italian English French Ger...

Page 17: ...trol the Vacuum s activation SENS activation with pellet reserve sensor Whenever the level of pellets in the primary tank falls below the minimum level sensor the Vacuum function is activated regardle...

Page 18: ...configurations Access is protected by an access key P5 The menu is reserved for expert users only access by non expert users can cause serious damage to the appliance objects and the environment as we...

Page 19: ...managed in high temperature mode maximum value of SET PUFFER DHW 55 C maximum value of SET PUFFER HEAT 75 C Sub menu 5 5 ROOM SENSOR Enables reading of an optional room sensor if present connected to...

Page 20: ...orking mode and to switch a three way motor driven valve to give it priority 2 Boiler with integrated instant DHW connected to a heating system combined with an alternative DHW generator Plant type 2...

Page 21: ...der will be managed during summer and the heating system will be left off 4 Boiler connected to a centralised puffer controlled by a H2O sensor connected to it Plant Type 4 involves connecting the boi...

Page 22: ...le generator proceed as follows Operation with PELLET FIRED BOILER ONLY Set OFF on the heat pump display or set Menu 12 HEAT PUMP OFF on the boiler display Operation with HEAT PUMP ONLY Set OFF on the...

Page 23: ...Warning before switching on the device make sure that there are no pellets in the brazier otherwise it is necessary to empty and clean the brazier We recommend that you use high quality pellets so as...

Page 24: ...cycle Modifying the working power and the temperatures of the room boiler water water heater or puffer TFT Display WORKING POWER To modify the maximum working power simply select SET POWER Fig 1 then...

Page 25: ...the back arrow During the working phase if the boiler is in demand the appliance will switch to Economy mode if T H2O SET BOILER 10 C Below are the operating modes in the event that the SET BOILER tem...

Page 26: ...be considered a manufacturing fault If ignition fails empty the pellets out of the brazier only then can you reignite the appliance in order to avoid gasification and consequent explosion during igni...

Page 27: ...NING and after cooling OFF FINAL CLEANING duration Pr48 FINAL CLEANING and after cooling OFF STOP FIRE any STOP FIRE Alarm signals The following table describes the different alarms which may appear D...

Page 28: ...aning operations may be carried out by the end user as indicated in the paragraph below Routine cleaning The routine cleaning of the appliance must be done at least every 10 days of operation or after...

Page 29: ...as follows Perform routine cleaning Remove the extractor smoke chamber front inspection plate by unscrewing the 4 screws Figure 4 Using the ash vacuum vacuum the residues inside it Figure 5 Remove the...

Page 30: ...riods of inactivity If the flue is not cleaned the operation of the appliance and its components may be compromised The cleaning frequency of the appliance and flue depends on the quality of the pelle...

Page 31: ...V BN K 01 1 VT K 11 2 PVS F 230V N 230V V1 VALVOLA MOTORIZZATA A TRE VIE Gestione ACS tipo impianto 1 2 3 GNYE Massa terra BN Lato riscaldamento Fase 230V quando ACS non in richiesta BK Lato sanitario...

Page 32: ...S Pulito NO 3_14 NC 2_12 W055 CN6 GND i1 230 V K 32 1 BU A2_1 A1_5 NC 2_12 NO 3_14 COM 4_11 BU K 31 1 A2_1 A1_5 W055 L023_8 CN10 CN8 04 N Pulito GY GY ntc 10K SB1 1 D4 RETE 230Vac 2 3 4 5 6 7 8 12V 12...

Page 33: ...entre finds that the reported defect is not one of the defects covered by the Warranty the call out and any works completed will be paid by the Consumer In order to improve the service and reduce inte...

Page 34: ...2 CS ECO TFT IST 1 EN Rev 1 0 ENGLISH...

Page 35: ...3 CS ECO TFT IST 1 EN Rev 1 0 ENGLISH...