THE TFT DISPLAY
REFERENCE
DESCRIPTION
OPERATION
1
Menu
Button for accessing the menu.
2
Date and time
Shows the set date and time.
3.1
Timer programme
Appears when at least one timer programme is active.
3.2
Puffer demand
Appears when the SET BOILER / SET PUFFER demand is active (request).
3.3
Heat pump
Appears when the heat pump is operating.
3.4
DHW demand
Appears when the DHW flow switch contact input is closed (demand for DHW).
3.5
Space heating
demand
Appears when the room thermostat contact input is closed (demand for space heating).
4
ON/OFF
On/off button.
5
Operating status
Shows the operating status.
6
Set power
Allows for accessing the power set-point (SET POWER).
- White border = Shows the set power.
- White filling = Shows the actual working power (modulation example).
7
Set room
Allows for accessing the SET ROOM set-point (field available only if ROOM SENSOR is enabled)
- Top value = Shows the room temperature.
- Bottom value = Shows the SET ROOM setting.
8
Water set-point
Allows for accessing SET H2O (field available only with plant type 1, 2, 3)
- Top value = Shows the temperature of the water in the boiler.
- Bottom value = Shows the SET H2O that has been set or that must be reached by modulation.
9
Set Boiler /
Set Puffer
Allows for accessing the SET BOILER / PUFFER (field available only with plant type 3, 4, 5)
- Top value = Shows the temperature of the water heater/puffer.
- Bottom value = Shows the SET BOILER/PUFFER set-point.
- Bottom value DHW = Shows the SET DHW PUFFER set-point. (Plant type 5)
- Bottom value HEATING = Shows the SET HEATING PUFFER set-point. (Plant type 5)
1
3.1 3.2 3.3 3.4 3.5
2
3
9
4
5
6
7
8