Fig.6-12
Fig.6-11
≥
400
≥
300
≥
300
b)In case that installing on the floor
≥
300
≥
400
≥
300
3. Centrifugal fan type outdoor unit
6.5 Moving and installation
6.4 Available configuration for centrifugal fan
type outdoor unit
Fig.6-15
>60cm
Fix with bolt
All the figures in this manual are for explanation
purpose only. They may be slightly different from the air
conditioner you purchased.The actual unit shall prevail.
Since the gravity center of the unit is not at its physical
center, so please be careful when lifting it with a sling.
Never hold the inlet of the outdoor unit to prevent it from
deforming.
Do not touch the fan with hands or other objects.
Do not lean it more than 45, and do not lay it sidelong.
Make concrete foundation accoding to the sepecif-ications of
the outdoor units.
(Refer to Fig.6-15)
Fasten the feet of this unit with bolts firmly to prevent it from
collapsing in case of earthquake or strong wind.
(Refer to
Fig.6-15)
NOTE
NOTE
Four different configuration are available for oudoor unit only
changing the panels and fan position.
Keep in mind that fan unit weight is aprox 30Kg ,the unit as
well as relevant equipment covered with the vinyl cover
during installation work.
To change air inlet is only necessary to interchange the
indicated panels position. Both panels
screws to be fixed
use
to unit chas is.
s
To change air outlet is necessary to interchange panels too.
Fan outlet panel is attached to fan structure, which must be
mounted as
.
Air inlet modification
follow
Change Panel
Fig6-13
Fig.6-14
1. Foundation could be on flat and is recommended be 100-300mm
higher than ground level.
2.Install a drainage around foundation for smooth drain
3.When installing the outdoor unit fix the unit by anchor bolts of M10
4.When installing the unit on a roof or a veranda,
water
drain
sometimes turns to ice on the cold weather. Therefore, avoid
Concrete Foundation
draining in an area that people often use because it is slippery.
Fig.6-16
≥
100
100
~
300
B
C