• Press again to return to normal operation.
• Press and hold to activate display backlight.
• Using lights drains the battery signifi cantly.
K. L. Battery/Fuse Replacement
• When
indicator is displayed on the LCD, batteries must be
replaced.
• Remove rubber boot, back screw and replace 2 x AAA batteries.
• This meter uses 440mA/1000V (69192) and 11A/1000V (69191)
fast blow fuses.
M. Magnetic Hanger Accessory (Optional, Sold Separately)
• Slide magnetic adapter into protective rubber boot.
• Attach instruments to metal for hands-free use
N.
Bar Graph
• The bar graph shows an approximate analog representation
of a measurement.
• The bar graph responds much faster than the digital display.
• The scale of the bar graph is zero to the maximum reading of
the selected range.
FUNCTION INSTRUCTIONS
1.
AC Voltage: <1000V. (Low Z) < 600V
Features:
MAX/MIN
RANGE
HOLD
REL
Do not attempt to measure more than 1000V
DO NOT use (LOW Z) mode at voltages greater than 600V.
• Use Low Impedance (LOW Z) mode to reduce ghost voltages.
• Rotate selector to "AC" Voltage position.
• Attach red lead to “V” input.
2.
DC Voltage: <1000V. (Low Z) < 600V
Features:
MAX/MIN
RANGE
HOLD
REL
AUTO HOLD
AUTO HOLD
AUTO/HOLD
0
10
20
30
40
50
60
MM2300
®
5
1
8
3
4
6
7
2
Do not attempt to measure more than 1000V
DO NOT use (LOW Z) mode at voltages greater than 600V.
• Use Low Impedance (LOW Z) mode to reduce ghost voltages.
• Rotate selector to "DC" Voltage position.
• Attach red lead to “V” input.