background image

WARRANTY

See www.kleintools.com, contact Klein Tools at 1-877-775-5346, or visit a 
distributor for warranty information.

CLEANING

Turn instrument off and disconnect test leads. Clean the instrument by using 
a damp cloth. Do not use abrasive cleaners or solvents.

STORAGE

Remove the batteries when instrument is not in use for a prolonged period of 
time. Do not expose to high temperatures or humidity. After a period of storage 
in extreme conditions exceeding the limits mentioned in the Specifi cations 
section, allow the instrument to return to normal operating conditions before 
using it.

DISPOSAL / RECYCLE

Caution: 

This symbol indicates that equipment and its accessories 

shall be subject to a separate collection and correct disposal.

Rev A 01/27/12 

139716

SYMBOLS USED ON LCD

~

AC Measurement

DC Measurement

-

Negative DC Value

AT

Auto Range Active

O.L.

Overload: Range Exceeded

Apo

Auto Power-Off Active

Low Battery

HOLD

Hold Active

MIN

Minimum Reading

MAX

Maximum Reading

%

Duty Cycle Mode

Frequency Mode

V

Voltage Measurement

A

Current in Amps

Ω

Resistance in Ohms

Diode Test

F

Capacitance in Farads

Continuity Test

Relative / Zero Mode

n

Nano 10

-9

µ

Micro 10

-6

m

Milli 10

-3

k

Kilo 10

3

M

Mega 10

6

°F

Degrees Fahrenheit

°C

Degrees Celsius

A-HOLD

Auto-Hold Active

LOW 

Z

Low Impedance

Test Equipment Depot - 800.517.8431 

99 Washington Street Melrose, MA 02176 

TestEquipmentDepot.com 

Summary of Contents for MM2300

Page 1: ...1 8 5 7 MM2300 TRMS BACKLIGHT BAR GRAPH LEAD HOLDER MAX MIN 3 5 6 DIGIT 6000 COUNT LCD AUTO MANUAL RANGE AUTO HOLD HOLD Apo AUTO RANGE TRMS A HOLD 99 Washington Street Melrose MA 02176 Phone 781 665...

Page 2: ...Never use the meter on a circuit with voltages that exceed the category based rating of this meter Do not use the meter during electrical storms or in wet weather Do not use the meter or test leads i...

Page 3: ...return to live reading H Auto Manual Range Press repeatedly to cycle through manual ranges Press for 2 seconds to return to auto ranging mode AT is displayed on LCD only during auto ranging mode I Ma...

Page 4: ...digital display The scale of the bar graph is zero to the maximum reading of the selected range FUNCTION INSTRUCTIONS 1 AC Voltage 1000V Low Z 600V Features MAX MIN RANGE HOLD REL Do not attempt to m...

Page 5: ...HOLD Display shows Forward voltage drop if forward biased O L if reverse biased AUTO HOLD MAX MIN RANGE HOLD REL Resistance Features Do not measure resistance on a live circuit 60M AUTO HOLD HOLD REL...

Page 6: ...eatures Testing Fuse When selecting uA or mA A functions the meter will indicate LEAd if the test leads are not properly connected to the meter Note This message remaining on the screen after properly...

Page 7: ...verload Protection 600V RMS Capacitance Measurement Range Resolution Accuracy 60nF 0 01nF 3 5 6 digits 600nF 6000 F 0 1nF 1 F Overload Protection 600V RMS Frequency Measurement Range Resolution Accura...

Page 8: ...it DISPOSAL RECYCLE Caution This symbol indicates that equipment and its accessories shall be subject to a separate collection and correct disposal Rev A 01 27 12 139716 SYMBOLS USED ON LCD AC Measure...

Reviews: