ENGLISH
ELECTRICAL SPECIFICATIONS
DC Voltage Measurement
Range
Resolution
Accuracy
600mV ˜ 600V
0.1mV ˜ 0.1V
± (0.5% + 4 digits)
1000V
1V
± (0.8% + 10 digits)
Overload Protection:
1000V
Input Impedance (Nominal)
: 10M
Ω
, <100pF
Input Impedance (Low Z)
: 3k
Ω
, <200pF, up to 600V RMS
AC Voltage Measurement
Range
Resolution
Accuracy
40Hz ~ 400Hz
Accuracy
400Hz ~ 5kHz
600mV
0.1mV
± (0.75% + 5 digits)
± (2.0% +3 digits)
6V ~ 600V
1mV ~ 0.1V
± (2.0% +3 digits)
1000V
1V
± (0.75% + 8 digits)
± (2.0% +3 digits)*
continued on next page.
Do Not apply voltage to thermocouple.
• Fahrenheit range: -58° to 1832°F (Celsius range: -50° to 1000° C)
8. Temperature:
Features:
Testing Fuse:
• When selecting uA or mA/A functions the meter will indicate
“LEAd” if the test leads are not properly connected to the meter.
• Note: This message remaining on the screen after properly
connecting the test leads is an indication that the fuse is open.
7.
Frequency (Hz) / Duty Cycle: <500kHz
Features:
HOLD
6.
Low Impedance (Low Z): < 600V
DO NOT use (LOW Z) mode at voltages greater than 600V.
• Press SELECT to choose AC or DC Voltage.
• Use Low Impedance (LOW Z) mode to reduce ghost voltages
• See AC/DC Voltage instruction
Capacitance Features:
HOLD
Safely discharge capacitor before
measurement.
• Reading may take up to 60 seconds
for large capacitors.
AUTO HOLD MAX/MIN
REL
HOLD