Overload Protection:

 1000V RMS 

Input Impedance (Nominal):

 10M

Ω

, <100pF 

Input Impedance (Low Z)

: 3k

Ω

, <200pF, up to 600V RMS

Frequency Response:

 40 to 5kHz

 Response:

 True RMS

*Accuracy for 400Hz ~ 1kHz range only.
DC Current Measurement

Range

Resolution

Accuracy

600µA ~ 400mA

0.1µA ~ 0.1mA

± (1.0% + 5 digits)

6A ~ 10A

1mA ~ 10mA

± (1.5% + 5 digits)

Overload Protection: µAmA: F440mA/1000V fuse / A Input: F11A/1000V fuse

AC Current Measurement

Range

Resolution

Accuracy 

40Hz ~ 2kHz

600µA ~ 400mA

0.1µA ~ 0.1mA

± (1.2% + 5 digits)

6A ~ 10A

1mA ~ 10mA

± (1.8% + 5 digits)

Overload Protection: µAmA: F440mA/1000V fuse / A Input: F11A/1000V fuse
Frequency:

 40 to 2kHz 

 

Response:

 True RMS

Resistance Measurement

Range

Resolution

Accuracy

600

Ω

˜ 6M

˜˜

Ω

0.1

Ω

˜ 0.001M

˜˜

Ω

± (1.0% + 5 digits)

60M

Ω

0.01M

Ω

± (1.5% + 10 digits)

Overload Protection:

 600V RMS

Capacitance Measurement

Range

Resolution

Accuracy

60nF

0.01nF

± (3.5% + 6 digits)

600nF ~ 6000µF

0.1nF ~ 1µF

Overload Protection: 

600V RMS

Frequency Measurement

Range

Resolution

Accuracy

99.99Hz ˜ 499.9kHz

˜˜

0.01Hz ˜ 0.1kHz

˜˜

± (0.1% + 3 digits)

Overload Protection:

 600V RMS 

Sensitivity:

 > 0.7V RMS

Duty Cycle Measurement

Range

Resolution

Accuracy

0.1 ˜ 99.9%

˜˜

0.1%

± (0.2% per kHz + 0.1% + 5 digits)

Overload Protection:

 600V RMS 

Sensitivity: 

< 50V

Frequency Range:

 <10kHz

Diode Test

Overload Protection

Range

Test Current

Open Circuit Voltage

600V RMS

6.0V

Appx. 0.25mA

< 1.8V DC (typ.)

Continuity Test

Overload Protection

Open Circuit Voltage

Threshold (Appx.)

600V RMS

< 0.44V

<40

Ω

Temperature Measurement

Range

Resolution

Accuracy

-58 ~ 600°F

0.1°F

± (1.0% + 5.4°F)

-50 ~ 600°C

0.1°C

± (1.0% + 3.0°C)

600 ~ 1832°F

1°F

± (1.0% + 5.4°F)

600 ~ 1000°C

1°C

± (1.0% + 3.0°C)

Overload Protection:

 600V RMS 

Thermocouple Accuracy:

 Not specifi ed

Specifi cations subject to change

Summary of Contents for MM2300

Page 1: ...1 8 5 7 MM2300 TRMS BACKLIGHT BAR GRAPH LEAD HOLDER MAX MIN 3 5 6 DIGIT 6000 COUNT LCD AUTO MANUAL RANGE AUTO HOLD HOLD Apo AUTO RANGE TRMS A HOLD 99 Washington Street Melrose MA 02176 Phone 781 665...

Page 2: ...Never use the meter on a circuit with voltages that exceed the category based rating of this meter Do not use the meter during electrical storms or in wet weather Do not use the meter or test leads i...

Page 3: ...return to live reading H Auto Manual Range Press repeatedly to cycle through manual ranges Press for 2 seconds to return to auto ranging mode AT is displayed on LCD only during auto ranging mode I Ma...

Page 4: ...digital display The scale of the bar graph is zero to the maximum reading of the selected range FUNCTION INSTRUCTIONS 1 AC Voltage 1000V Low Z 600V Features MAX MIN RANGE HOLD REL Do not attempt to m...

Page 5: ...HOLD Display shows Forward voltage drop if forward biased O L if reverse biased AUTO HOLD MAX MIN RANGE HOLD REL Resistance Features Do not measure resistance on a live circuit 60M AUTO HOLD HOLD REL...

Page 6: ...eatures Testing Fuse When selecting uA or mA A functions the meter will indicate LEAd if the test leads are not properly connected to the meter Note This message remaining on the screen after properly...

Page 7: ...verload Protection 600V RMS Capacitance Measurement Range Resolution Accuracy 60nF 0 01nF 3 5 6 digits 600nF 6000 F 0 1nF 1 F Overload Protection 600V RMS Frequency Measurement Range Resolution Accura...

Page 8: ...it DISPOSAL RECYCLE Caution This symbol indicates that equipment and its accessories shall be subject to a separate collection and correct disposal Rev A 01 27 12 139716 SYMBOLS USED ON LCD AC Measure...

Reviews: