![Klein Marine Systems, Inc. MA-X VIEW 600 Operation And Maintenance Manual Download Page 28](http://html1.mh-extra.com/html/klein-marine-systems-inc/ma-x-view-600/ma-x-view-600_operation-and-maintenance-manual_1977128028.webp)
2-4
CHAPTER 2 Specifications
MA-X View 600 Sonar System Operations and Maintenance Manual P/N 11210097, Rev. 00
2.6.2 Sensors
Compass
Heading accuracy, level:
±0.5°
∞
RMS
Heading accuracy, tilted:
±1.0°
∞
RMS, <±30°
tilt
±1.5°
∞
RMS, ±30°
to ±60°
∞
tilt
Heading resolution:
0.1°
∞
Pitch range:
±90°
∞
Roll range:
±180°
∞
Pitch and roll accuracy:
±1° at <±30°
∞
tilt
Pressure sensor
Pressure range:
0–450 psi
Pressure accuracy:
1.0% of full scale
Temperature sensor
Temperature range:
-40–125°C
2.7
Tow Cables
Both lightweight and armored coaxial tow cables are available. A 50-meter
lightweight coaxial tow cable is included with an SP-III TPU.
2.7.1 Lightweight Coaxial Tow Cable
Type:
Polyurethane jacketed coaxial, Kevlar
reinforced
Conductors:
Coaxial copper
Diameter (OD):
1.156 cm (0.455 in.)
Breaking strength:
2270 kg (5000 lb)
Working load:
454 kg (1000 lb)
Operational length:
300 m maximum
Voltage rating:
600 VDC
Summary of Contents for MA-X VIEW 600
Page 30: ......
Page 54: ......
Page 77: ...SP III TPU 5 7 Figure 5 3 SP III TPU Electronics Block Diagram...
Page 86: ......
Page 92: ......
Page 96: ......
Page 99: ...D 3...
Page 103: ...E 3...
Page 105: ...E 5...
Page 106: ......
Page 109: ...F 3...
Page 111: ...F 5...
Page 113: ...F 7...
Page 115: ...F 9...
Page 117: ...F 11...
Page 119: ...F 13...
Page 121: ...F 15...
Page 123: ...F 17...
Page 125: ...F 19...
Page 126: ......