Instruction
Manual
SSG
page
24
___________________________________________________________________________
9. Technical Data
Safety cutting unit
Operating pressure:
625 bar
Hydraulic oil:
"Special- Transformer Oil Rivolta S.B.H.11"
High grade bio-degradable, not hazardous to water
Temperature range:
-20°C to 40°C
Pump Type SHP 5
Length:
ca. 625 mm
Width:
ca. 195 mm
Height:
ca. 160 mm
max. operating pressure:
625 bar
Weight with oil:
ca. 12 kg
Available oil volume
1,3 l
Used oil volume:
1,0 l
Oil flow per stroke
In the high pressure range:
2,5 cm³
In the low pressure range:
25 cm³
Insulating hose Type Europower (CIJN) 852
Inside diameter:
4 mm
Outside diameter:
13,2 mm
Min. bending radius:
38 mm
dyn. Operating pressure:
689 bar
min. burst pressure:
2758 bar
Weight with fittings:
3,5 kg
Length between the fittings:
10,3 m
Cutting heads Type SSK
Head
max.
cable-
∅
operating pressure
unit type
Total weight
______________________________________________________________________________________________________
SSK 85/3
85 mm
625 bar
SSG 85/3
26 kg
SSK 90/2
90 mm
625 bar
SSG 90/2
31 kg
SSK 120/2
120 mm
625 bar
SSG 120/2
32 kg
Note
This instruction manual is available free of charge. The part # is HE.10075.