44
EN
Electrical safety requirements
• Be sure to use the rated voltage and air conditioners dedicated circuit for the power
supply, and the power cord diameter must meet the national requirements.
•
When the maximum current of air conditioner is greater than or equal to 16 A,
it must use the air switch or leakage protection switch equipped with protection
devices.
•
The operating range is 90–110 % of the local rated voltage. But insufficient power
supply malfunction, electrical shock, or fire. If the voltage instability, proposed to
increase the voltage regulator.
•
The minimum clearance between the air conditioner and the combustibles is 1.5 m.
•
The interconnection cord connect the indoor and outdoor units. You must first choose
the right cable size before preparing it for connection.
•
Cable Types: Outdoor Power Cable: H07RN-F or H05RN-F;
Interconnection Cord: H07RN-F or H05RN-F
• Minimum Cross-Sectional Area of power cable and interconnection cord.
Rated current of appliance (A)
Nominalcross-sectionalarea(mm²)
> 3 und ≤ 6
0.75
> 6 und ≤ 10
1
> 10 und ≤ 16
1.5
> 16 und ≤ 25
2.5
> 25 und ≤ 32
4
> 32 und ≤ 40
6
• The size of the interconnection cord, power cable, fuse, and switch needed is
determined by the maximum current of the unit. The maximum current is indicated
on the nameplate located on the side panel of the unit. Refer to this nameplate to
choose the right cable, fuse, or switch.
Note:
Core number of cable refer to the detailed wiring diagram adhered on the unit
which you purchased.