EN
INSTALLATION
Important notices
• Before installation, please contact an local authorized maintenance center. If the
unit is not installed by the authorized maintenance center, the malfunction may not
solved due to lack of contact.
• The air conditioner must be installed by professionals according to the national
wiring rules and this manual.
• Refrigerant leak test must be made after installation.
• To move and install air conditioner to another place, please contact costumer
service.
Unpacking inspection
• Open the box and check air conditioner in area with good ventilation (open the
door and window) and without ignition source.
• Operators are required to wear anti-static devices.
• It is necessary to check by professional whether there is refrigerant leakage before
opening the box of the outdoor machine. Stop installing the air conditioner if
leakage is found.
•
The fire prevention equipment and anti-static precautions shall be prepared well
before checking. Then check the refrigerant pipeline to see if there is any collision
traces, and whether the outlook is good.
Requirements for installation position
•
Avoid places of inflammable or explosive gas leakage or where there are strongly
aggressive gases.
•
Avoid places subject to strong artificial electric/magnetic fields.
• Avoid places subject to noise and resonance.
• Avoid severe natural conditions (e.g. heavy hail, strong sandy wind, direct sunshine
or high temperature heat sources).
• Avoid places within the reach of children.
• Shorten the connection between the indoor and outdoor units.
• Select where it is easy to perform service and repair and where the ventilation
good.
• The outdoor unit shall not be installed in any way that could occupy an aisle,
stairway, exit, fire escape, catwalk or any other public area.
• The outdoor unit shall be installed as far as possible from the doors and windows of
the neighbours as well as the green plants.
Installation environment inspection
• Check nameplate of outdoor unit to make sure whether the refrigerant is R32.
•
Check the floor space of the room. The space shall not be less than usable space
(5 m²) in the specification. The outdoor unit shall be installed at a well-ventilated
place.