background image

28

DN9610 AES50 Repeater

klarkteknik.com

1. Register 

online.

  

Please register your new Klark Teknik 
equipment right after you purchase it 
by visiting klarkteknik.com. Registering 
your purchase using our simple online 
form helps us to process your repair 
claims more quickly and effi  ciently. 
Also, read the terms and conditions of 
our warranty, if applicable.

2. Malfunction.

 Should your 

MUSIC Group Authorized Reseller not be 
located in your vicinity, you may contact 
the MUSIC Group Authorized Fulfi ller for 
your country at klarkteknik.com. If your 
country is not listed please contact the 
“United Kingdom (Midas/KT main offi  ce)” 
located under “Service Service/
Repairs” on the klarkteknik.com 
website. Alternatively, please submit 
the online warranty return form found 
under “Service Warranty Registration” 
on klarkteknik.com BEFORE returning 
the product. All enquires must be 
accompanied by the description of the 
problem and the serial number of the 
product. The warranty eligibility will be 
verifi ed from the original sales receipt.

3. Power 

Connections.

 Before 

plugging the unit into a power socket, 
please make sure you are using the 
correct mains voltage for your particular 
model. Faulty fuses must be replaced 
with fuses of the same type and rating 
without exception.

1. Registro 

online.

 

Le recomendamos que registre su nuevo 
aparato Klark Teknik justo después 
de su compra accediendo a la página 
web klarkteknik.com. El registro de 
su compra a través de nuestro sencillo 
sistema online nos ayudará a resolver 
cualquier incidencia que se presente a 
la mayor brevedad posible. Además, 
aproveche para leer los términos y 
condiciones de nuestra garantía, si es 
aplicable en su caso.

2. Averías. 

En el caso de que 

no exista ningún distribuidor MUSIC 
Group en su ciudad o región, póngase 
en contacto con el distribuidor MUSIC 
Group de su país, que podrá localizar en 
nuestra página web klarkteknik.com. Si 
su país no aparece en el listado, póngase 
en contacto con “United Kingdom 
(Midas/KT main offi  ce)” {“Reino Unido 
(sede central de Midas/KT)”} que 
encontrará en el enlace “Service Service/
Repairs” {“Reparaciones Reparaciones/
mantenimiento”} dentro de la página 
web general klarkteknik.com. De forma 
alternativa, también puede remitirnos 
el formulario online de devolución en 
periodo de garantía que encontrará 
en “Service Warranty Registration” 
{“Reparaciones Registro de garantía”} 
de nuestra web klarkteknik.com ANTES 
de devolvernos el aparato. Todas las 
solicitudes deberán ir acompañadas 
de una descripción del problema y del 
número de serie del aparato. La vigencia 
del periodo de garantía será comprobada 
con el recibo de compra o factura original.

3.  Conexiones de corriente.

 

Antes de enchufar este aparato a una 
salida de corriente, asegúrese de que 
dicha salida sea del voltaje adecuado 
para su modelo concreto. En caso de 
que deba sustituir un fusible quemado, 
deberá hacerlo por otro de idénticas 
especifi caciones, sin excepción.

1. Enregistrez-vous 

en 

ligne.

 Prenez le temps d’enregistrer 

votre produit Klark Teknik aussi 
vite que possible sur le site Internet 
klarkteknik.com. Le fait d’enregistrer le 
produit en ligne nous permet de gérer 
les réparations plus rapidement et plus 
effi  cacement. Prenez également le 
temps de lire les termes et conditions de 
notre garantie.

2. Dysfonctionnement.

 Si vous 

n’avez pas de revendeur MUSIC Group 
à proximité, contactez le distributeur 
MUSIC Group de votre pays à l’adresse 
klarkteknik.com. Si votre pays n’est pas 
indiqué, contactez le “United Kingdom 
(Midas/KT main offi  ce)” {“bureau du 
Royaume-Uni (siège social de Midas/
KT)”} situé dans “Service Service/Repairs” 
{“Réparations Maintenance/Réparations”} 
du site Internet klarkteknik.com. 
Vous pouvez également soumettre en 
ligne le formulaire de retour sous garantie 
dans “Service Warranty Registration” 
{“Réparations Enregistrement de 
garantie”} sur le site klarkteknik.com 
AVANT de renvoyer le produit. Toutes les 
requêtes doivent être accompagnées de 
la description du problème et du numéro 
de série du produit. La prise en charge par 
la garantie sera validée par la facture de 
vente initiale.

Important information

Aspectos importantes

Informations importantes

Other important information

Summary of Contents for DN9610 AES50

Page 1: ...DN9610 AES50 Repeater User Manual klarkteknik com DOC02 DN9610UM1 Issue A...

Page 2: ...ercordfrombeing walkedonorpinchedparticularlyat plugs conveniencereceptacles andthe pointwheretheyexitfromtheapparatus 11 Useonlyattachments accessories specifiedbythemanufacturer 12 Useonlywith theca...

Page 3: ...abilitenuncala conexi natierradelaparatoodelcable dealimentaci ndecorriente Unenchufe polarizadotienedospolos unodelos cualestieneuncontactom sanchoque elotro Unaclavijaconpuestaatierra disponedetresc...

Page 4: ...sures Neposezpasder cipient contenantunliquidesurl appareil unvaseparexemple Attention Cesconsignesdes curit et d entretiensontdestin es unpersonnelqualifi Pour vitertout risquedechoc lectrique n effe...

Page 5: ...ng dassdieGefahr einesStromschlagsbesteht Verwenden Sienurhochwertige professionelle Lautsprecherkabelmitvorinstallierten 6 35mmMONO Klinkensteckern oderLautsprechersteckermit Drehverriegelung Alleand...

Page 6: ...mtoderzuIhrem Haushaltsabfallentsorgerauf TECHNISCHEDATENUND ERSCHEINUNGSBILDK NNEN UNANGEK NDIGTGE NDERTWERDEN IRRT MERBLEIBENVORBEHALTEN MIDASUNDKLARKTEKNIKSINDTEIL DESMUSICGROUP MUSIC GROUP COM ALL...

Page 7: ...s riaumarepara o semprequeaunidadetiversidode algumaformadanificada comopor exemplo nocasodocabodealimenta o oufichaseencontraremdanificados naeventualidadedel quidotersido derramadoouobjectosteremca...

Page 8: ...S50 repeater 2 x AES50 Ethercon inputs and outputs AES50 activity LED per input and output 2 x 9V to 18V DC power supply inputs second DC power supply option for redundancy External DC power supply un...

Page 9: ...2Cdigitalconsole Typicalmulti unitconnectiondiagram forexample threeunitsare daisychained A Toclockslave B Toclockmaster AES50 IN 1 AES50 OUT 1 AES50 OUT 2 AES50 IN 2 A B AES50 OUT 1 AES50 OUT 2 AES50...

Page 10: ...ts 1 and 2 3 Green LEDs for indicating the activity on AES50 input ports 1 and 2 4 POWER LED to show when the power is on 5 Rear Panel 1 2 3 5 DC inlet power sockets for accepting lockable power suppl...

Page 11: ...ood working order and to make sure it gives you optimum performance we recommend that you carry out the following every month Clean the unit using a dry lint free cloth Don t use harsh abrasives or so...

Page 12: ...a entrada y salida 2 x tomas de fuente de alimentaci n de 9 a 18 V DC opci n de segunda fuente de alimentaci n DC para sistemas redundantes Fuente de alimentaci n DC exterior con conector con enganche...

Page 13: ...ladigitalPRO2C Diagramadet picaconexi nmulti unidad enestecaso tresunidades conectadasenserieo daisy chain A Aesclavodereloj B Amasterdereloj AES50 IN 1 AES50 OUT 1 AES50 OUT 2 AES50 IN 2 A B AES50 OU...

Page 14: ...e entrada AES50 1 y 2 4 Piloto POWER que le indica en qu momento est encendida la unidad 5 Panel trasero 1 2 3 1 Tomas de entrada DC que admiten los conectores con enganche de seguridad de la fuente d...

Page 15: ...na Limpie la unidad usando un trapo suave seco y que no suelte pelusas No utilice nunca ning n disolvente ni l quidos abrasivos Compruebe que todos los pilotos funcionen correctamente Compruebe el cor...

Page 16: ...ur chaque entr e et chaque sortie 2 entr es d alimentation 9 Vcc 18 Vcc deuxi me option d alimentation en tension continue pour la redondance Bloc d alimentation en tension continue externe avec fiche...

Page 17: ...lenum riquePRO2C Sch madeconnexiontypiqueentreplusieursbo tiers parexemple troisbo tiersconnect sens rie A Versl horlogeesclave B Versl horlogema tre AES50 IN 1 AES50 OUT 1 AES50 OUT 2 AES50 IN 2 A B...

Page 18: ...ntr es AES50 1 et 2 4 Led POWER indiquant la mise sous tension 5 Face arri re 1 2 3 1 Embases d alimentation recevant les fiches verrouillage portant l alimentation en tension continue Vous n avez bes...

Page 19: ...pour vous garantir des performances optimales il est conseill de proc der comme suit une fois par mois Nettoyez l appareil avec un tissu sec et non pelucheux N utilisez pas de produits abrasifs ou de...

Page 20: ...Ethercon Eing nge und Ausg nge AES50 Aktivit ts LED pro Eingang und Ausgang 2 x 9V bis 18V DC Anschl sse zur Spannungs versorgung zweiter DC Anschluss zur Absicherung Externes DC Netzteil mit verrieg...

Page 21: ...RO2CDigitalmischpult DiagrammeinertypischenMehrfachverkabelung z B Verkettung dreierGer te A zumClockSlave Ger t B zumClockMaster Ger t AES50 IN 1 AES50 OUT 1 AES50 OUT 2 AES50 IN 2 A B AES50 OUT 1 AE...

Page 22: ...den AES50 Ausgangs Ports 1 und 2 an 3 Gr ne LEDs zeigen Aktivit ten an den AES50 Eingangs Ports 1 und 2 an 4 POWER LED leuchtet bei eingeschaltetem Ger t 5 R ckseite 1 2 3 1 DC Eing nge f r verriegel...

Page 23: ...ng mit dem Repeater zu erzielen sollten Sie monatlich folgende Wartungsarbeiten durchf hren Reinigen Sie das Ger t mit einem trockenen fusselfreien Tuch Verwenden Sie keine scharfen Reinigungs oder L...

Page 24: ...das AES50 Ethercon LED de atividade AES50 por entrada e sa da 2 x entradas de fonte de alimenta o de 9V a 18V DC segunda fonte de alimenta o DC opcional para redund ncia Unidade de fonte de alimenta...

Page 25: ...mesadigitalPRO2Cdigital Diagramadeconex odem ltiplasunidades porexemplo tr s unidadesest oligadasemcadeia A Paraclockslave B Paraclockmaster AES50 IN 1 AES50 OUT 1 AES50 OUT 2 AES50 IN 2 A B AES50 OUT...

Page 26: ...ES50 1 e 2 3 LEDs verdes para indicar atividade nas portas das entradas AES50 1 e 2 4 LED POWER para indicar que a unidade est ligada 5 Painel Traseiro 1 2 3 1 Tomadas de entrada DC que aceitam conect...

Page 27: ...anuten o de rotina Para ajud lo a manter sua unidade em boas condi es de funcionamento e ter seu melhor desempenho garantido recomendamos que a cada m s os seguintes procedimentos sejam seguidos Limpe...

Page 28: ...KTmainoffice ReinoUnido sedecentraldeMidas KT que encontrar enelenlace ServiceService Repairs ReparacionesReparaciones mantenimiento dentrodelap gina webgeneralklarkteknik com Deforma alternativa tamb...

Page 29: ...r ft 3 Stromanschluss BevorSie dasGer taneineNetzsteckdose anschlie en pr fenSiebitte obSie diekorrekteNetzspannungf rIhr speziellesModellverwenden Fehlerhafte Sicherungenm ssenausnahmslosdurch Sicher...

Page 30: ...esigned to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy an...

Page 31: ...loi dans sa totalit Nous esp rons que vous l avez trouv utile N h sitez pas nous faire part de vos commentaires Nos cordonn es et l adresse de notre site Internet sont indiqu es au d but de ce mode d...

Page 32: ...rk Industrial Park Walter Nash Road Kidderminster Worcestershire DY11 7HJ England Tel 44 1562 741515 Fax 44 1562 745371 Email mkt info music group com Website klarkteknik com 2012 MUSIC Group IP Limit...

Reviews: