6

 Maintenance  

7

 Safety precautions

a. External cleaning of the breast pump

Cleaning is confined to external parts. 
Disinfection is done with a clean, damp cloth.

b. Cleaning the protective membrane

The protective membrane prevents any ingress of milk or liquid into the tubing 
and into the device. 
It is important to clean it as soon as it has been in contact with breast milk. 
Also clean the small tubing connecting to the breast shield.

 

Cleaning:

  

Disconnect the large and small tubing 
from both sides of the protective 
membrane.

  Disconnect the large and small tubing 

from both sides of the protective 
membrane.

  Clean and rinse all parts of the 

protective membrane and the small 
contaminated tubing to remove liquid 
residue. Allow to air dry on a paper 
towel.

  Assemble the 3 pieces of the protective membrane. Check that the white 

diaphragm is correctly positioned in its housing (press on the edges to ensure 
a good seal throughout the membrane contour). Reconnect the small and 
large tubing to the protective membrane.

4

1

2

3

Use of electricity 

•  Before connecting the appliance to an electrical outlet, check the values in the 

operating instructions of the appliance (volts and Hz) and your distribution network.

• Warranty does not cover connection errors.
• The unit is designed to operate at an altitude of 3000m or less.
• Do not open the device when switched on.
•  Beware, this equipment is connected to the electrical system, do not use in the 

bathtub or shower, do not submerge it.

• Keep the device away from strong sources of heat.
• When using the AC power adapter, stand about 1.5m away from the power supply.
•  Plug the unit into an easily accessible outlet to allow a quick disconnection from the 

network.

Using the breast pump

•  The device can be used by the patient himself. 
•  This device must not be left within the reach of unsupervised children or animals 

(potential hazards with tubing and detachable components).

•  The device should be installed and started up in accordance with the information 

supplied in the accompanying documents.

• Store the power cord and tubing properly.
•  An animal may gnaw at the power cord. Be sure to check the condition of the 

equipment before use.

•  Do not use the appliance outdoors, near a heat source or near a water source 

(bathtub, sink ...).

• Make sure the unit is not exposed to direct sunlight or excessive heat.
• After use, unplug the appliance from the wall outlet.

Summary of Contents for MINIKIT SOLO

Page 1: ...Contents MINIKIT SOLO by GB INSTRUCTIONS FOR USE p 5 ES INSTRUCCIONES DE USO p 31 PT MANUAL DE UTILIZA O p 57 GR p 83 NO BRUKSANVISNING p 109 FI K YTT OHJE p 135 GB PT GR NO ES FI...

Page 2: ...n of accessories p 13 c Using the breast pump p 14 d After each use p 16 5 Breastfeeding p 17 a Breast milk preservation p 17 b Physiology of baby breastfeeding p 17 6 Maintenance p 18 a External clea...

Page 3: ...who wish to continue feeding their babies b Contraindications and adverse effects There are no known contraindications to the use of the MINIKIT SOLO electric breast pump The MINIKIT SOLO breast pump...

Page 4: ...K comfort sizes S L inside diameters Non contractual photographs The KOLORYOU application available for free download 21 mm 24 mm 26 mm 30 mm The Clean Valve to be used with the MINIKIT SOLO pump must...

Page 5: ...lizer and do not exceed 1000 Watt Note If disinfection takes place in boiling water and your water is hard you can add a few drops of white vinegar 2 or 3 drops to avoid deposits on the walls of the p...

Page 6: ...educed If the device is not used for an extended period of time remove the batteries from the compartment 1 2 5 6 3 4 1 2 5 1 2 3 4 5 6 7 8 CLIC CLIC 3 4 CLIC 1 2 5 1 2 3 4 5 6 7 8 CLIC CLIC 3 4 CLIC...

Page 7: ...ically stops after 30 minutes of expression regardless of the setting level chosen 3 4 5 6 1 2 00 00 00 00 01 00 3 4 5 6 1 2 00 00 00 00 01 00 c Using the breast pump Place the breast shield correctly...

Page 8: ...IKIT SOLO Breast Pump provides mothers with the natural sensation of breastfeeding by recreating the way in which babies feed It reproduces the 2 physiological phases of the breastfeeding The stimulat...

Page 9: ...electrical outlet check the values in the operating instructions of the appliance volts and Hz and your distribution network Warranty does not cover connection errors The unit is designed to operate a...

Page 10: ...l cases WARNING Always unplug the power cord before opening the device WARNING Caution only authorized service personnel are authorized to service a device WARNING Modification prohibited WARNING Use...

Page 11: ...B24SH WB24LH WB26SH WB26LH WB30SH WB30LH Other countries References WB21ESH WB24ESH WB26ELH WB30ELH The collection container and its cap can be autoclaved at 125 C for 30 minutes or at 134 C for 18 mi...

Page 12: ...id Recycling Kitett breast pumps must be disposed of in accordance with local disposal guidelines for electrical appliances Use your local waste disposal system for electrical and electronic equipment...

Page 13: ...as this may cause a malfunction If this is necessary this appliance and the other appliances should be monitored for normal operation WARNING Use of accessories transducers and cables other than thos...

Page 14: ...r power lines 1 kV for input output lines 2 kV 1 kV Transient overvoltage IEC 61000 4 5 1 kV between phases 2 kV between phase and earth 1 kV between phases 2 kV between phase and earth Voltage dips s...

Page 15: ...de repuesto disponibles p 48 10 Garant a y reciclaje p 50 11 Especificaciones t cnicas p 51 12 Compatibilidad Electromagn tica CEM p 53 13 Pictogramas p 55 This symbol indicates the moisture limit wh...

Reviews: