Kitett MINIKIT SOLO Instructions For Use Manual Download Page 7

15

GB

14

GB

Level 1 automatically switches to level 2 after 1min30.
Level 2 automatically switches to level 3 after 1min30.
If the first drops of milk begin to flow more quickly, press 
the 

+

 button to go directly to level 3 in the expression 

phase.

  

Levels 3, 4 and 5

 correspond to the 

expression phase

 (with 

an increasingly slower speed, the suction power becomes 
more important). Upon the arrival of the milk and for an 
optimal collection, adjust the position to your convenience 
according to the comfort felt. Milk expression is optimal at 
the level of maximum depression and is not painful for 
the mother.

   At any time in the expression cycle, you can press the 

-

button to go back to the lower setting level.

Be sure to check the proper flow of milk inside the collection 
bottle.

  After having expressed the milk, deactivate the breast 

pump by pressing the on/off button.

      

The MINIKIT SOLO Breast Pump automatically stops 
after 30 minutes of expression, regardless of the setting 
level chosen.

3

4

5

6

1

2

00:00

00:00

01:00

3

4

5

6

1

2

00:00

00:00

01:00

c. Using the breast pump

➊  

Place the breast shield correctly over your breast 
ensuring the milk can flow freely into the collection 
container.

  

Ensure your nipple is centred inside the funnel. The 
flexible part of the breast shield must also be properly 
positioned on your breast to ensure complete sealing.

   

Activate the breast pump by pressing the on/off button. 
Suction is activated. A time counter is displayed to allow 
you to track the duration of the expression session.

  

The MINIKIT SOLO breast pump operates with 

5 setting 

levels

 that are gradually displayed on the right and left 

corner of the display screen.

  

To move from one level to another, press the 

+

 or 

-

buttons.

    

Levels 1 and 2

 correspond to the 

stimulation phase

(fast rate, low suction). When first starting to use the device, 
it is necessary to start with this stimulation phase in order 
to stimulate the arrival of the milk and to activate the milk 
ejection reflex. This phase should last about 2 min.

Summary of Contents for MINIKIT SOLO

Page 1: ...Contents MINIKIT SOLO by GB INSTRUCTIONS FOR USE p 5 ES INSTRUCCIONES DE USO p 31 PT MANUAL DE UTILIZA O p 57 GR p 83 NO BRUKSANVISNING p 109 FI K YTT OHJE p 135 GB PT GR NO ES FI...

Page 2: ...n of accessories p 13 c Using the breast pump p 14 d After each use p 16 5 Breastfeeding p 17 a Breast milk preservation p 17 b Physiology of baby breastfeeding p 17 6 Maintenance p 18 a External clea...

Page 3: ...who wish to continue feeding their babies b Contraindications and adverse effects There are no known contraindications to the use of the MINIKIT SOLO electric breast pump The MINIKIT SOLO breast pump...

Page 4: ...K comfort sizes S L inside diameters Non contractual photographs The KOLORYOU application available for free download 21 mm 24 mm 26 mm 30 mm The Clean Valve to be used with the MINIKIT SOLO pump must...

Page 5: ...lizer and do not exceed 1000 Watt Note If disinfection takes place in boiling water and your water is hard you can add a few drops of white vinegar 2 or 3 drops to avoid deposits on the walls of the p...

Page 6: ...educed If the device is not used for an extended period of time remove the batteries from the compartment 1 2 5 6 3 4 1 2 5 1 2 3 4 5 6 7 8 CLIC CLIC 3 4 CLIC 1 2 5 1 2 3 4 5 6 7 8 CLIC CLIC 3 4 CLIC...

Page 7: ...ically stops after 30 minutes of expression regardless of the setting level chosen 3 4 5 6 1 2 00 00 00 00 01 00 3 4 5 6 1 2 00 00 00 00 01 00 c Using the breast pump Place the breast shield correctly...

Page 8: ...IKIT SOLO Breast Pump provides mothers with the natural sensation of breastfeeding by recreating the way in which babies feed It reproduces the 2 physiological phases of the breastfeeding The stimulat...

Page 9: ...electrical outlet check the values in the operating instructions of the appliance volts and Hz and your distribution network Warranty does not cover connection errors The unit is designed to operate a...

Page 10: ...l cases WARNING Always unplug the power cord before opening the device WARNING Caution only authorized service personnel are authorized to service a device WARNING Modification prohibited WARNING Use...

Page 11: ...B24SH WB24LH WB26SH WB26LH WB30SH WB30LH Other countries References WB21ESH WB24ESH WB26ELH WB30ELH The collection container and its cap can be autoclaved at 125 C for 30 minutes or at 134 C for 18 mi...

Page 12: ...id Recycling Kitett breast pumps must be disposed of in accordance with local disposal guidelines for electrical appliances Use your local waste disposal system for electrical and electronic equipment...

Page 13: ...as this may cause a malfunction If this is necessary this appliance and the other appliances should be monitored for normal operation WARNING Use of accessories transducers and cables other than thos...

Page 14: ...r power lines 1 kV for input output lines 2 kV 1 kV Transient overvoltage IEC 61000 4 5 1 kV between phases 2 kV between phase and earth 1 kV between phases 2 kV between phase and earth Voltage dips s...

Page 15: ...de repuesto disponibles p 48 10 Garant a y reciclaje p 50 11 Especificaciones t cnicas p 51 12 Compatibilidad Electromagn tica CEM p 53 13 Pictogramas p 55 This symbol indicates the moisture limit wh...

Reviews: