Kitett MINIKIT SOLO Instructions For Use Manual Download Page 5

11

GB

10

GB

Inside
diameter

Nipple

Size L

Size S

Breast shield

or

3

   Cleaning   

and disinfecting accessories 

• Before using for the first time and after each use:

a. Cleaning  

-  Rinse all the parts in contact with the milk in cold water, then clean 

with hot and soapy water.

-  Rinse all parts. Assemble the two parts of the valve: the diaphragm 

on the intermediate ring (making sure that the valve is nested in 
the ring). Assemble the three parts making up the protective 
membrane. Check that the white diaphragm is correctly positioned 
in its housing (press down on the edges to ensure a good seal 
around the membrane) 

- Allow to air dry on a paper towel.

  

 Note: It is best to clean all parts in contact with breast milk 
immediately after using the breast pump. This facilitates cleaning 
and avoids the development of bacteria.

• Before first use and regularly during use:

b. Disinfecting at home

Disinfect all parts in boiling water (10 minutes minimum), in a 
dishwasher or in a microwave steriliser. * 

*Refer to the manufacturer’s data for the microwave sterilizer and do not exceed 1000 Watt.

   

Note: If disinfection takes place in boiling water and your water is hard, you 
can add a few drops of white vinegar (2 or 3 drops) to avoid deposits on the 
walls of the parts.

• 

Special case: 

If condensation appears in the pipe or when milk enters inside, rinse 

the tubing to remove liquid residue.

3

4

5

6

1

2

KOLOR

®

 breast shields are guaranteed BPA and Phthalate free.

They are reusable for as long as the breast pump is used. The breast shield is a one-piece 
which favors an optimized hygiene, and makes it possible not to touch the thread nor the 
internal parts of the feeding collection container and the breast shield.

Measurements:

Measurement should be taken after breastfeeding or expressing your milk. Alternatively, 
“when at rest”, add an extra 2mm to your nipple measurement to select the correct 
inner diameter size.

The nipple should not feel too constricted neither too free. You should see space around 
your nipple in order to let it move easily in the funnel during pumping.

- If the breast shield is too tight: lesions, compressed ducts

- if the breast shield is too wide: less milk will be expressed 

A correct comfort size (external S or L comfort shape) will improve breast pump 
(optimal airtightness).

Summary of Contents for MINIKIT SOLO

Page 1: ...Contents MINIKIT SOLO by GB INSTRUCTIONS FOR USE p 5 ES INSTRUCCIONES DE USO p 31 PT MANUAL DE UTILIZA O p 57 GR p 83 NO BRUKSANVISNING p 109 FI K YTT OHJE p 135 GB PT GR NO ES FI...

Page 2: ...n of accessories p 13 c Using the breast pump p 14 d After each use p 16 5 Breastfeeding p 17 a Breast milk preservation p 17 b Physiology of baby breastfeeding p 17 6 Maintenance p 18 a External clea...

Page 3: ...who wish to continue feeding their babies b Contraindications and adverse effects There are no known contraindications to the use of the MINIKIT SOLO electric breast pump The MINIKIT SOLO breast pump...

Page 4: ...K comfort sizes S L inside diameters Non contractual photographs The KOLORYOU application available for free download 21 mm 24 mm 26 mm 30 mm The Clean Valve to be used with the MINIKIT SOLO pump must...

Page 5: ...lizer and do not exceed 1000 Watt Note If disinfection takes place in boiling water and your water is hard you can add a few drops of white vinegar 2 or 3 drops to avoid deposits on the walls of the p...

Page 6: ...educed If the device is not used for an extended period of time remove the batteries from the compartment 1 2 5 6 3 4 1 2 5 1 2 3 4 5 6 7 8 CLIC CLIC 3 4 CLIC 1 2 5 1 2 3 4 5 6 7 8 CLIC CLIC 3 4 CLIC...

Page 7: ...ically stops after 30 minutes of expression regardless of the setting level chosen 3 4 5 6 1 2 00 00 00 00 01 00 3 4 5 6 1 2 00 00 00 00 01 00 c Using the breast pump Place the breast shield correctly...

Page 8: ...IKIT SOLO Breast Pump provides mothers with the natural sensation of breastfeeding by recreating the way in which babies feed It reproduces the 2 physiological phases of the breastfeeding The stimulat...

Page 9: ...electrical outlet check the values in the operating instructions of the appliance volts and Hz and your distribution network Warranty does not cover connection errors The unit is designed to operate a...

Page 10: ...l cases WARNING Always unplug the power cord before opening the device WARNING Caution only authorized service personnel are authorized to service a device WARNING Modification prohibited WARNING Use...

Page 11: ...B24SH WB24LH WB26SH WB26LH WB30SH WB30LH Other countries References WB21ESH WB24ESH WB26ELH WB30ELH The collection container and its cap can be autoclaved at 125 C for 30 minutes or at 134 C for 18 mi...

Page 12: ...id Recycling Kitett breast pumps must be disposed of in accordance with local disposal guidelines for electrical appliances Use your local waste disposal system for electrical and electronic equipment...

Page 13: ...as this may cause a malfunction If this is necessary this appliance and the other appliances should be monitored for normal operation WARNING Use of accessories transducers and cables other than thos...

Page 14: ...r power lines 1 kV for input output lines 2 kV 1 kV Transient overvoltage IEC 61000 4 5 1 kV between phases 2 kV between phase and earth 1 kV between phases 2 kV between phase and earth Voltage dips s...

Page 15: ...de repuesto disponibles p 48 10 Garant a y reciclaje p 50 11 Especificaciones t cnicas p 51 12 Compatibilidad Electromagn tica CEM p 53 13 Pictogramas p 55 This symbol indicates the moisture limit wh...

Reviews: