![KitchenAid KUDD03DT Technical Education Download Page 59](http://html.mh-extra.com/html/kitchenaid/kudd03dt/kudd03dt_technical-education_195445059.webp)
5-3
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
WARNING
DRAIN PUMP MOTOR
Refer to page 4-7 for procedure for servicing
the drain pump motor.
1. Unplug dishwasher or disconnect power.
2. Disconnect the wire connectors from the
DRAIN PUMP MOTOR terminals on drain
pump motor.
3. Set the ohmmeter to the R x 1 scale.
4. Touch the ohmmeter test leads to drain
pump motor terminals. The meter should
indicate between 23 and 32
Ω
.
Drain Motor Terminals
HEATING ELEMENT
Refer to page 4-10 for procedure for servicing
the heating element.
1. Unplug dishwasher or disconnect power.
2. Disconnect the wire connectors from the
HEATING ELEMENT terminals on heating
element.
3. Set the ohmmeter to the R x 1 scale.
4. Touch the ohmmeter test leads to heat-
ing element terminals. The meter should
indicate approximately 25.4
Ω
.
Heater Element Terminals