2-4
ELECTRICAL REQUIREMENTS
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can
result in death, fire, or electrical shock.
WARNING
GROUNDING INSTRUCTIONS
For a grounded, cord-connected
•
dishwasher:
The dishwasher must be grounded. In the
event of a malfunction or breakdown, ground-
ing will reduce the risk of electric shock by
providing a path of least resistance for
electric current. The dishwasher is equipped
with a cord having an equipment-grounding
conductor and a grounding plug. The plug
must be plugged into an appropriate outlet
that is installed and grounded in accordance
with all local codes and ordinances.
WARNING:
Improper connection of the
equipment-grounding conductor can result
in a risk of electric shock. Check with a quali-
fied electrician or service representative if
you are in doubt whether the dishwasher is
properly grounded. Do not modify the plug
provided with the dishwasher; if it will not
fit theoutlet, have a proper outlet installed
by a qualified electrician.
For a permanently connected
•
dishwasher:
The dishwasher must be connected to a
grounded metal, permanent wiring system,
or an equipment grounding conductor must
be run with the circuit conductors and con-
nected to the equipment grounding terminal
or lead on the dishwasher.
Contact a qualified electrician.
Ensure that the electrical installation is adequate
and in conformance with all national and local
codes and ordinances.
You must have:
120-volt, 60 Hz, AC-only, 15 or 20 amp fused
•
electrical supply.
Copper wire only.
•
We recommend:
A time-delay fuse or circuit breaker.
•
A separate circuit.
•
If direct wiring dishwasher:
Use flexible, armored or nonmetalic sheathed,
•
copper wire with grounding wire that meets
the wiring requirements for your home and
local codes and ordinances.
Use strain relief method provided with house
•
wiring junction box or install a UL-listed/CSA-
certified clamp connector to the house wiring
junction box. If using conduit, use a UL-listed/
CSA-certified conduit connector.
If connecting dishwasher with a power sup-
ply cord:
Use Power Supply Cord Kit (Part Number
•
4317824) marked for use with dishwashers.
Kit contents include:
Voltex, Inc., UL listed 16 gauge 3 wire power
•
supply cord with 3 prong grounded plug.
Neer C-500 7/8" strain relief.
•
3 wire connectors.
•
Part Number 302797 grommet.
•
Follow the kit instructions for installing the power
supply cord.
Power supply cord must plug into a mating
•
three prong, grounded outlet, located in the
cabinet next to the dishwasher opening. Outlet
must meet all local codes and ordinances.
IMPORTANT:
If you plan to install a garbage
disposer, an additional separate 120-volt, 60 Hz,
AC-only, 15 or 20 amp fused electrical supply
is required.
Summary of Contents for KUDD03DT
Page 12: ...1 8 NOTES ...
Page 30: ...2 18 NOTES ...
Page 36: ...3 6 NOTES ...
Page 56: ...4 20 NOTES ...
Page 62: ...5 6 NOTES ...
Page 64: ...6 2 Fault Codes ...
Page 65: ...7 1 WIRING DIAGRAM DRAWER HARNESS WIRING DIAGRAM ...
Page 66: ...7 2 UPPER FRAME HARNESS ...
Page 67: ...7 3 LOWER FRAME HARNESS ...
Page 68: ...7 4 SINGLE FRAME HARNESS ...
Page 70: ......