12
4.
Tighten the locking screw against the bottom collar of the
20 lb LP gas fuel tank to secure.
5.
Slide tank tray back into the cabinet.
6.
Close cabinet doors.
Local LP Gas Supply Conversion
Conversion must be made by a qualified gas technician. The
qualified gas technician shall provide the gas supply to the
selected grill location in accordance with the National Fuel Gas
Code ANSI Z223.1/NFPA 54 - latest edition, and local codes. For
conversion to local LP, the convertible regulator in the conversion
kit supplied with the grill must be used.
IMPORTANT:
The gas installation must conform with local
codes, or in the absence of local codes, with the National Fuel
Gas Code, ANSI Z223.1/NFPA 54 - latest edition. The qualified
LP gas technician shall provide the LP gas supply to the selected
grill location in accordance with the National Fuel Gas Code,
ANSI Z223.1/NFPA 54 and local codes.
Follow instructions for converting to local LP gas in the “Gas
Conversions” section.
The gas supply line shall be equipped with an approved shutoff
valve. This valve should be located in the same area as the grill
and should be in a location that allows ease of opening and
closing. Do not block access to the shutoff valve. The valve is for
turning on or shutting off gas to the grill.
Natural Gas Conversion
Conversion must be made by a qualified gas technician. The
qualified Natural gas technician shall provide the Natural gas
supply to the selected grill location in accordance with the
National Fuel Gas Code ANSI Z223.1/NFPA 54 - latest edition,
and local codes. For conversion to Natural gas, the Natural gas
conversion kit supplied with the grill must be used.
IMPORTANT:
The gas installation must conform with local
codes, or in the absence of local codes, with the National Fuel
Gas Code, ANSI Z223.1/NFPA 54 - latest edition.
To convert to Natural gas, the Natural Gas Conversion Kit
supplied with the grill must be used. Follow instructions for
converting to Natural gas in the “Gas Conversions” section.
The gas supply line shall be equipped with an approved shutoff
valve. This valve should be located in the same area as the grill
and should be in a location that allows ease of opening and
closing. Do not block access to the shutoff valve. The valve is for
turning on or shutting off gas to the grill.
A. Locking screw
B. Mounting hole
C. Bottom collar
A. New CSA International approved
“outdoor” flexible gas supply line
B. Rear of grill
C. To local LP gas supply
A
B
C
B
C
A
A. Gas supply line
B. Shutoff valve “open” position
C. To grill
A. New CSA International approved
“outdoor” flexible gas supply line
B. Rear of grill
C. To Natural gas supply
A. Gas supply line
B. Shutoff valve “open” position
C. To grill
A
B
C
B
C
A
A
B
C
Summary of Contents for KBNS271TSS
Page 39: ...39 Notes ...