3-3
THE BLOWER & CONVECTION FAN MOTORS
BLOWER MOTOR
Refer to page 2-7 for the procedure for servic-
ing the blower motor.
1.
Disconnect the electrical power to the
microwave oven.
2.
Disconnect the wires from the blower motor
terminals.
3.
Set the ohmmeter to the R x 1 scale.
4.
Touch the ohmmeter leads to the motor
terminals. The meter should indicate ap-
proximately 25
Ω
.
CONVECTION FAN MOTOR
Refer to page 2-16 for the procedure for servic-
ing the convection fan motor.
1.
Disconnect the electrical power to the
microwave oven.
2.
Disconnect the wires from the convection
fan motor terminals.
3.
Set the ohmmeter to the R x 1 scale.
4.
Touch the ohmmeter leads to the motor
terminals. The meter should indicate ap-
proximately 40
Ω
.
Electrical Shock Hazard
Disconnect power before servicing.
Replace all panels before operating.
Failure to do so could result in death or
electrical shock.
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all panels before operating.
Failure to do so could result in death or
electrical shock.
WARNING