2-21
d) Disconnect the two filament wires from
the magnetron terminals.
c) Unclip the two wires from the right air
duct and remove the duct.
e) Remove the four T-16 magnetron torx
screws and remove the magnetron.
NOTE: Move the left air duct back far
enough to access the magnetron
screws.
IMPORTANT REASSEMBLY NOTE:
When
you mount the magnetron, loosely install the
four screws, and then tighten them in a cross-
tightening (opposite corner) sequence. Make
sure that the base of the magnetron stays
parallel with the mounting surface so that it is
not tilted; otherwise, it may not work properly.
Screw (1 of 4)
Filament Wires
Left Air Duct Screw Right Air Duct Screw
Wire Clip
6.
To remove the magnetron:
a) Remove the magnetron thermal fuse
(see step 5).
b) Remove the T-16 torx screws (1 each)
from the left and right air ducts.